Cervical length measurement
Cervical length measurement is an ultrasound check of how long the cervix is in pregnancy. A 2021 review calls the scan through the vagina the gold standard, because it predicts preterm birth better than other routes. The same review says that most clinical guidelines it reviewed recommend screening between 16 and 24 weeks for women with a past preterm birth and that screening women with no such history is still debated. A 2026 review of screening every woman, followed by progesterone for a short cervix, found it uncertain whether this lowers preterm birth. This page gives no advice on when to scan.
Also called Cervical length screening · Transvaginal cervical length scan
- Intervention
- In this atlas
Overview
Technical summary
Procedure (a test; MeSH D054791, exact, which MeSH defines as a parameter used in prenatal ultrasonography). Sources read: the MeSH concept scope note; a 2021 narrative review of cervical assessment (PMC7915684); and a 2026 systematic review of universal cervical length screening with progesterone (PMC13356482), all CC BY 4.0, with the review abstracts and selected paragraphs read. Not read: any guideline, so the atlas gives no recommended schedule or threshold. The 2026 review is the only source on benefit; the 2021 narrative review reports predictive accuracy.
About this intervention
- Type
- Test
- Mechanism
- Not reported
Claims and evidence
Context A vocabulary definition (MeSH), not a study population
- Recipient
- No clinical recipient
- Population
- Not applicable: a controlled-vocabulary definition from the National Library of Medicine, with no population.
- Care setting
- Not applicable (vocabulary)
- Geography
- Not applicable (vocabulary)
- Life stage
- Not applicable (vocabulary)
- Follow-up
- Not applicable (vocabulary)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Not applicable (vocabulary)
- Excluded
- None stated
The National Library of Medicine vocabulary MeSH defines cervical length as a parameter usually used in prenatal ultrasonography to measure the length of the uterine neck (cervix).
Applies to No clinical recipient A vocabulary definition (MeSH), not a study population
- Certainty method
- Not assessed
- Limitations
- A vocabulary definition for anyone, not a recommendation about when to scan.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
Supports MeSH concept M0507662 (preferred concept of descriptor D054791, Cervical Length Measurement)
- Locator
- scopeNote.@value
- How it applies
- MeSH scope note (NLM, attribution given). A definition, not a clinical finding.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
556b04169034cf9dd246e97b95a403efd169d4e8d3b38eea3b65a4a75d989ef9- Reuse basis
- The NLM web policies page (https://www.nlm.nih.gov/web_policies.html), re-read 2026-11-18 (sha256 c8b7026b5c3fcfd1b0cb88755077f6a99a5f2159eecd42b0e7d1a5ad9b30ec55, hash only), says works produced by the U.S. government are not subject to copyright protection in the United States and asks users to acknowledge NLM as the source. Source: National Library of Medicine. This copy was fetched on 2026-11-18 and may not reflect the most current data. The raw bytes are committed in the atlas repository.
Context Pregnant women having cervical length measured by ultrasound, as a 2021 review describes it
- Recipient
- Maternal
- Population
- Pregnant women who have the length of the cervix measured by ultrasound to predict spontaneous preterm birth, as the authors of a narrative review of cervical assessment describe it. Most of the review concerns women without symptoms.
- Care setting
- Antenatal ultrasound care, as the review describes it
- Geography
- Not stated (narrative review; guidelines of several countries are named)
- Gestational age
- Not reported
- Postnatal age
- Not reported
- Follow-up
- Not applicable (narrative review)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Pregnant women, mainly without symptoms, who have a cervical length scan
- Excluded
- None stated
The 2021 narrative review reports that how well a short cervical length predicts preterm birth depends mainly on the cutoff used, with a reported sensitivity of a length of 25 mm or less that varies widely, from 6% to 76%, among women at high and low risk.
Applies to Maternal Pregnant women having cervical length measured by ultrasound, as a 2021 review describes it
- Certainty method
- Not assessed
- Limitations
- A range quoted by a narrative review from other studies. It does not say which studies sit at each end, and this atlas did not read them.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
Supports Cervical Assessment for Predicting Preterm Birth—Cervical Length and Beyond
- Locator
- 5.1. What Cervical Length Threshold Should Be Used for Prediction of sPTL?, paragraph 1
- How it applies
- Full-text open-access narrative review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
e404a0364b5f04ec932388ef0818c110235ec7f89a5f46ccf3ac04ae5decc1a3- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
The 2021 narrative review says that most clinical guidelines it reviewed recommend screening between 16 and 24 weeks for women without symptoms who have had a preterm birth, that the length should not be measured routinely before 16 weeks, and that screening every woman with a singleton pregnancy and no earlier spontaneous preterm birth remains a matter of debate.
Applies to Maternal Pregnant women having cervical length measured by ultrasound, as a 2021 review describes it
- Certainty method
- Not assessed
- Limitations
- This is the review’s account of guidelines, which this atlas did not read, and no recommendation of this atlas. The review is dated 2021.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
Supports Cervical Assessment for Predicting Preterm Birth—Cervical Length and Beyond
- Locator
- 4. What Is the Optimal Gestational Age for Cervical Length Screening?, paragraph 1; 6. Who to Screen?, paragraph 2
- How it applies
- Full-text open-access narrative review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
e404a0364b5f04ec932388ef0818c110235ec7f89a5f46ccf3ac04ae5decc1a3- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
A 2021 narrative review says that cervical length measured by a transvaginal scan predicts preterm birth better than other routes, so it is considered the gold standard, and that all the randomised trials showing benefit of treatment for women with a short cervix used the transvaginal scan.
Applies to Maternal Pregnant women having cervical length measured by ultrasound, as a 2021 review describes it
- Certainty method
- Not assessed
- Limitations
- The review’s own statement from other studies, which this atlas did not read. A narrative review and not a systematic review. It does not give how the scan is done.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
Supports Cervical Assessment for Predicting Preterm Birth—Cervical Length and Beyond
- Locator
- 5. The Preferred Approach of Cervical Length Measurement, paragraph 1; 5. The Preferred Approach of Cervical Length Measurement, paragraph 2
- How it applies
- Full-text open-access narrative review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
e404a0364b5f04ec932388ef0818c110235ec7f89a5f46ccf3ac04ae5decc1a3- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
Context Women with singleton pregnancies and no symptoms who are offered cervical length screening, and their babies, in a 2026 review
- Recipient
- Mixed recipients
- Population
- Women with a singleton pregnancy and no symptoms who have a mid-trimester vaginal ultrasound cervical length screen followed by progesterone if the cervix is short, compared with no screening, as the authors of a 2026 systematic review set out the question. Two randomised trials and four cohort studies were pooled. The outcomes counted are preterm birth (the pregnant woman) and perinatal and neonatal death and illness (the fetus and newborn), so the claim is not split between mother and baby.
- Care setting
- Antenatal care (trials and cohort studies)
- Geography
- Not stated in the abstract
- Life stage
- Mid-trimester screening in singleton pregnancies
- Gestational age
- Not reported
- Postnatal age
- Not reported
- Follow-up
- Until birth, with preterm birth and neonatal outcomes counted
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Women with a singleton pregnancy and no symptoms
- Excluded
- None stated
A 2026 systematic review of screening every woman for cervical length, followed by progesterone for a short cervix, found in its two randomised trials no statistically significant reduction in preterm birth, perinatal or neonatal death, or illness. The authors say it is uncertain, on very low certainty evidence, whether the approach lowers preterm birth or changes the outcomes of the babies, and that larger trials are needed.
Applies to Mixed recipients Women with singleton pregnancies and no symptoms who are offered cervical length screening, and their babies, in a 2026 review
- Certainty method
- Not assessed
- Limitations
- Two trials with 1634 women. The cohort studies, which showed lower odds of preterm birth, had very low certainty evidence and no data on newborn outcomes. The review judges that the result cannot be called a benefit of screening itself. Certainty is the authors’, not assessed here.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
- Locator
- Abstract, Results, paragraph 1; Abstract, Conclusions, paragraph 1
- How it applies
- Full-text open-access systematic review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
c6ef2e4421790a26b4e1d3b9c82a4d2fb2ca89d7f50b507f65e9eb48e7d8069e- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
Clinical links
Each link reports what one cited claim says about one population. "Evaluated for" means studied, not shown to work. These links do not show that anything is effective or right for you.
-
Claim, not a settled fact A 2026 systematic review of screening every woman and giving progesterone for a short cervix: Preterm birth
Applies to Mixed recipients Women with singleton pregnancies and no symptoms who are offered cervical length screening, and their babies, in a 2026 review
A 2026 systematic review of screening every woman for cervical length, followed by progesterone for a short cervix, found in its two randomised trials no statistically significant reduction in preterm birth, perinatal or neonatal death, or illness. The authors say it is uncertain, on very low certainty evidence, whether the approach lowers preterm birth or changes the outcomes of the babies, and that larger trials are needed.Limitations. Two trials with 1634 women. The cohort studies, which showed lower odds of preterm birth, had very low certainty evidence and no data on newborn outcomes. The review judges that the result cannot be called a benefit of screening itself. Certainty is the authors’, not assessed here.
Record details
- Record id
maternal:cervical-length-measurement- Content hash
d48961ca525ff31a871cffbb6613935e03afcd188dc2415a956441a10952ac90