Vacuum extractor devices

A vacuum extractor is a suction cup device used to help with delivery. US federal rules identify the fetal vacuum extractor as a device that applies traction to the fetal head through a suction cup attached to the scalp and place the generic type in Class II. Reviews report that vacuum extraction carries a lower risk of maternal perineal trauma than forceps but higher failure rates and more scalp injury in babies, that soft and rigid cups trade failure against scalp injury, and that the evidence behind device design is thin. This page describes the device type, not any brand, and gives no advice on use.

Also called Vacuum-assisted delivery devices · Fetal vacuum extractors · Vacuum cups for assisted birth

  • Product
  • In this atlas

Overview

Technical summary

Product, subtype device; a generic device type, not a single brand or model. FDA product code HDB (Extractor, Vacuum, Fetal), 21 CFR 884.4340, device class 2 (openFDA device classification record fetched 2026-11-19; eCFR text for 2026-11-01). Two open-access reviews were read: a 2020 engineering review (PMC7780266, CC BY 4.0) and a 2026 expert commentary that proposes an ultrasound method (PMC13024969, CC BY 4.0). Their statements about other studies cite works not read. No manufacturer, brand or 510(k) summary was read, so no other product record is linked. The operative vaginal birth record holds the care-pathway claims and is linked, not repeated. The commentary's proposed method and any technique, traction, timing or gestational-age rules are left out.

Product details

Type
Device
Model or formulation
Fetal vacuum extractor as a generic device type (FDA product code HDB, 21 CFR 884.4340); no single brand or model
Version
Regulation text as returned by the eCFR for 2026-11-01; classification record as fetched on 2026-11-19

Intended-use sources

  1. Background 21 CFR 884.4340 Fetal vacuum extractor (eCFR)

    Regulator · Office of the Federal Register and U.S. Government Publishing Office (eCFR) · Edition eCFR section text as returned by the versioner API for 2026-11-01. The first request, made without a gzip encoding header, was not accepted; the committed file is the decompressed response to the second request.

    Locator
    Whole source
    How it applies
    Source of the stated intended use
    Retrieved
    Source effective date
    Not reported
    Source state
    Current
    Version fingerprint
    c3eec01f4ee3d562b635c2ec7e10b2799eea5be930268eb96a6123ea87d5b24d
    Reuse basis
    Text of a US federal regulation. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c, read on 2026-10-14 for maternal:ecfr-21-cfr-880-5690 and not fetched again in this session) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. The eCFR is an editorial compilation and is not the legal edition of the CFR. The raw file is committed in the atlas repository.
  2. Background openFDA device classification records matching the device name vacuum extractor (product code HDB, Extractor, Vacuum, Fetal)

    Dataset · U.S. Food and Drug Administration (openFDA device classification endpoint) · Edition openFDA device classification search result fetched on 2026-11-19 (openFDA data last updated 2026-11-09). It holds one record: Extractor, Vacuum, Fetal (HDB).

    Locator
    Whole source
    How it applies
    Source of the stated intended use
    Retrieved
    Source effective date
    Not reported
    Source state
    Current
    Version fingerprint
    471215c51af1b0dce8833165dedaf40a89a49e19f5ae3fbf5ff38acbc0c2b07d
    Reuse basis
    openFDA data is public domain under a Creative Commons CC0 1.0 Universal dedication unless noted (https://open.fda.gov/terms/, https://open.fda.gov/license/). The raw file is committed in the atlas repository.
  3. Background An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

    Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

    Locator
    Whole source
    How it applies
    Source of the stated intended use
    Retrieved
    Source effective date
    Not reported
    Source state
    Current
    Version fingerprint
    3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
    Reuse basis
    PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
  4. Background Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

    Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

    Locator
    Whole source
    How it applies
    Source of the stated intended use
    Retrieved
    Source effective date
    Not reported
    Source state
    Current
    Version fingerprint
    8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
    Reuse basis
    PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Claims and evidence

Context Babies born with a vacuum extractor (reviews 2020 and 2026)

Recipient
Newborn
Population
Babies delivered with a vacuum cup on the scalp, as described by the reviews. Figures are background statements from other studies the atlas has not read.
Care setting
Hospital labour wards.
Geography
Not stated in the source
Life stage
Birth and the first days after birth; the sources give no age band
Gestational age
Not reported
Postnatal age
Not reported
Follow-up
Not applicable (literature review)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
  • Babies delivered with a vacuum extractor
Excluded
None stated
  • Safety Evidence synthesis Certainty not assessed

    Reviews report scalp and head injuries in babies after vacuum birth. The 2026 commentary lists cephalohematoma and intracranial hemorrhage among the complications of vacuum extraction and says that, compared with forceps, vacuum extraction carries a higher risk of neonatal scalp injury. The 2020 review gives subgaleal haematomas in approximately 6 in 10,000 vacuum deliveries, and the commentary cites a retrospective cohort study in which cup detachment went with higher rates of subgaleal hematoma (8.9% compared with 3.5%).

    Applies to Newborn Babies born with a vacuum extractor (reviews 2020 and 2026)

    Certainty method
    Not assessed
    Limitations
    Background statements that cite studies the atlas did not read; the figures come from different populations and definitions and are not combined. Certainty is not assessed here.
    Last checked
    2026-11-19
    Next evidence check due
    Not scheduled
    Sources and citations (5)
    1. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      Abstract, paragraph 1, sentence 1
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    2. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 1, sentence 3
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    3. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 1, sentence 2
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    4. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      Clinical use of VAD systems, paragraph 6, sentence 4
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    5. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      1. Introduction, paragraph 5, sentence 2
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Context US federal device rules for fetal vacuum extractors, not a study population

Recipient
No clinical recipient
Population
No population. The text identifies and classifies a generic type of medical device in United States rules.
Care setting
Not applicable.
Geography
United States.
Life stage
Not applicable
Follow-up
Not applicable (regulatory context).
Eligibility: inclusion criteria not stated; exclusion criteria not stated
Included
None stated
Excluded
None stated
  • Regulatory Evidence stage not applicable Certainty not assessed

    Title 21 of the Code of Federal Regulations, section 884.4340 (eCFR text returned for 1 November 2026), identifies a fetal vacuum extractor as a device used to facilitate delivery, applying traction to the fetal head in the birth canal by a suction cup attached to the scalp and powered by an external vacuum source, and classifies the generic type as Class II (performance standards). The openFDA classification record for the device lists the product code HDB, the name Extractor, Vacuum, Fetal, and device class 2.

    Applies to No clinical recipient US federal device rules for fetal vacuum extractors, not a study population

    Certainty method
    Not assessed
    Limitations
    A federal classification of a generic device type, not a statement about any brand or about safety or benefit in use. openFDA states that its data are unvalidated and not for medical decisions. The record lists many 510(k) numbers; none was read. The eCFR is an editorial compilation, not the legal edition.
    Last checked
    2026-11-19
    Next evidence check due
    Not scheduled
    Sources and citations (8)
    1. Supports 21 CFR 884.4340 Fetal vacuum extractor (eCFR)

      Regulator · Office of the Federal Register and U.S. Government Publishing Office (eCFR) · Edition eCFR section text as returned by the versioner API for 2026-11-01. The first request, made without a gzip encoding header, was not accepted; the committed file is the decompressed response to the second request.

      Locator
      884.4340 (a) Identification, sentence 1
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      c3eec01f4ee3d562b635c2ec7e10b2799eea5be930268eb96a6123ea87d5b24d
      Reuse basis
      Text of a US federal regulation. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c, read on 2026-10-14 for maternal:ecfr-21-cfr-880-5690 and not fetched again in this session) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. The eCFR is an editorial compilation and is not the legal edition of the CFR. The raw file is committed in the atlas repository.
    2. Supports 21 CFR 884.4340 Fetal vacuum extractor (eCFR)

      Regulator · Office of the Federal Register and U.S. Government Publishing Office (eCFR) · Edition eCFR section text as returned by the versioner API for 2026-11-01. The first request, made without a gzip encoding header, was not accepted; the committed file is the decompressed response to the second request.

      Locator
      884.4340 (a) Identification, sentence 2, part 1
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      c3eec01f4ee3d562b635c2ec7e10b2799eea5be930268eb96a6123ea87d5b24d
      Reuse basis
      Text of a US federal regulation. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c, read on 2026-10-14 for maternal:ecfr-21-cfr-880-5690 and not fetched again in this session) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. The eCFR is an editorial compilation and is not the legal edition of the CFR. The raw file is committed in the atlas repository.
    3. Supports 21 CFR 884.4340 Fetal vacuum extractor (eCFR)

      Regulator · Office of the Federal Register and U.S. Government Publishing Office (eCFR) · Edition eCFR section text as returned by the versioner API for 2026-11-01. The first request, made without a gzip encoding header, was not accepted; the committed file is the decompressed response to the second request.

      Locator
      884.4340 (a) Identification, sentence 2, part 2
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      c3eec01f4ee3d562b635c2ec7e10b2799eea5be930268eb96a6123ea87d5b24d
      Reuse basis
      Text of a US federal regulation. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c, read on 2026-10-14 for maternal:ecfr-21-cfr-880-5690 and not fetched again in this session) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. The eCFR is an editorial compilation and is not the legal edition of the CFR. The raw file is committed in the atlas repository.
    4. Supports 21 CFR 884.4340 Fetal vacuum extractor (eCFR)

      Regulator · Office of the Federal Register and U.S. Government Publishing Office (eCFR) · Edition eCFR section text as returned by the versioner API for 2026-11-01. The first request, made without a gzip encoding header, was not accepted; the committed file is the decompressed response to the second request.

      Locator
      884.4340 (b) Classification
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      c3eec01f4ee3d562b635c2ec7e10b2799eea5be930268eb96a6123ea87d5b24d
      Reuse basis
      Text of a US federal regulation. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c, read on 2026-10-14 for maternal:ecfr-21-cfr-880-5690 and not fetched again in this session) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. The eCFR is an editorial compilation and is not the legal edition of the CFR. The raw file is committed in the atlas repository.
    5. Supports openFDA device classification records matching the device name vacuum extractor (product code HDB, Extractor, Vacuum, Fetal)

      Dataset · U.S. Food and Drug Administration (openFDA device classification endpoint) · Edition openFDA device classification search result fetched on 2026-11-19 (openFDA data last updated 2026-11-09). It holds one record: Extractor, Vacuum, Fetal (HDB).

      Locator
      results[0].device_name
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      471215c51af1b0dce8833165dedaf40a89a49e19f5ae3fbf5ff38acbc0c2b07d
      Reuse basis
      openFDA data is public domain under a Creative Commons CC0 1.0 Universal dedication unless noted (https://open.fda.gov/terms/, https://open.fda.gov/license/). The raw file is committed in the atlas repository.
    6. Supports openFDA device classification records matching the device name vacuum extractor (product code HDB, Extractor, Vacuum, Fetal)

      Dataset · U.S. Food and Drug Administration (openFDA device classification endpoint) · Edition openFDA device classification search result fetched on 2026-11-19 (openFDA data last updated 2026-11-09). It holds one record: Extractor, Vacuum, Fetal (HDB).

      Locator
      results[0].product_code
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      471215c51af1b0dce8833165dedaf40a89a49e19f5ae3fbf5ff38acbc0c2b07d
      Reuse basis
      openFDA data is public domain under a Creative Commons CC0 1.0 Universal dedication unless noted (https://open.fda.gov/terms/, https://open.fda.gov/license/). The raw file is committed in the atlas repository.
    7. Supports openFDA device classification records matching the device name vacuum extractor (product code HDB, Extractor, Vacuum, Fetal)

      Dataset · U.S. Food and Drug Administration (openFDA device classification endpoint) · Edition openFDA device classification search result fetched on 2026-11-19 (openFDA data last updated 2026-11-09). It holds one record: Extractor, Vacuum, Fetal (HDB).

      Locator
      results[0].device_class
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      471215c51af1b0dce8833165dedaf40a89a49e19f5ae3fbf5ff38acbc0c2b07d
      Reuse basis
      openFDA data is public domain under a Creative Commons CC0 1.0 Universal dedication unless noted (https://open.fda.gov/terms/, https://open.fda.gov/license/). The raw file is committed in the atlas repository.
    8. Supports openFDA device classification records matching the device name vacuum extractor (product code HDB, Extractor, Vacuum, Fetal)

      Dataset · U.S. Food and Drug Administration (openFDA device classification endpoint) · Edition openFDA device classification search result fetched on 2026-11-19 (openFDA data last updated 2026-11-09). It holds one record: Extractor, Vacuum, Fetal (HDB).

      Locator
      results[0].regulation_number
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      471215c51af1b0dce8833165dedaf40a89a49e19f5ae3fbf5ff38acbc0c2b07d
      Reuse basis
      openFDA data is public domain under a Creative Commons CC0 1.0 Universal dedication unless noted (https://open.fda.gov/terms/, https://open.fda.gov/license/). The raw file is committed in the atlas repository.

Context Women having an operative vaginal birth with a vacuum extractor or forceps (2026 commentary)

Recipient
Maternal
Population
Women having an instrumental vaginal birth; the commentary summarises Cochrane review findings on perineal trauma and success of vaginal birth for vacuum extraction compared with forceps.
Care setting
Hospital labour wards.
Geography
Not stated in the source
Life stage
Second stage of labour
Gestational age
Not reported
Postnatal age
Not reported
Follow-up
Not applicable (literature commentary)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
  • Women having a vacuum or forceps birth in the trials the commentary summarises
Excluded
None stated
  • Effect Evidence synthesis Certainty not assessed

    A 2026 expert commentary says that vacuum extraction has gained popularity because of a lower risk of maternal perineal trauma than with forceps, and, citing randomised evidence summarised by Cochrane reviews, that forceps are more likely to achieve vaginal birth than vacuum extraction but carry higher rates of severe maternal perineal trauma.

    Applies to Maternal Women having an operative vaginal birth with a vacuum extractor or forceps (2026 commentary)

    Certainty method
    Not assessed
    Limitations
    The commentary summarises reviews and trials it does not reproduce; the atlas did not read them. No figures are given in the passage. Certainty is not assessed here.
    Last checked
    2026-11-19
    Next evidence check due
    Not scheduled
    Sources and citations (2)
    1. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      1. Introduction, paragraph 1, sentence 5
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    2. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 1, sentence 2
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Context Women having an operative vaginal birth with a vacuum extractor, and their babies (engineering review 2020; commentary 2026)

Recipient
Mixed recipients
Population
Women having a vacuum-assisted birth and the babies whose scalp the cup is placed on, as described in an engineering review and an expert commentary. Neither is a study population.
Care setting
Hospital labour wards and delivery rooms, where the reviews place instrumental birth.
Geography
UK and US usage figures are quoted in the sources; not itemised here.
Life stage
Second stage of labour
Gestational age
Not reported
Postnatal age
Not reported
Follow-up
Not applicable (literature review)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
  • Women and babies in vacuum-assisted vaginal birth, as described in the two reviews
Excluded
None stated
  • Effect Evidence synthesis Certainty not assessed

    The 2026 commentary reports that historical randomised trials found soft cups to have higher failure and detachment rates than rigid or metal cups, although with fewer scalp injuries. It also reports a comparison in which one cup design had a significantly higher failure rate than conventional vacuum cups (30.1% compared with 19.2%; relative risk 1.58, 95% CI 1.10 to 2.24), and says that randomised and pragmatic trials suggest severe neonatal outcomes remain broadly comparable between disposable and metal devices. The 2020 review adds that unintentional cup detachments are the most prevalent clinical adverse event with these devices.

    Applies to Mixed recipients Women having an operative vaginal birth with a vacuum extractor, and their babies (engineering review 2020; commentary 2026)

    Certainty method
    Not assessed
    Limitations
    A second-hand summary of trials the atlas did not read; no cup model is named here. Certainty is not assessed here.
    Last checked
    2026-11-19
    Next evidence check due
    Not scheduled
    Sources and citations (4)
    1. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 2, sentence 2
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    2. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 2, sentence 4
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    3. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 2, sentence 6
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    4. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      VAD mechanics & performance, paragraph 5, sentence 1
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
  • Description Evidence synthesis Certainty not assessed

    The 2020 review traces how the devices changed: pliable cups made from elastomeric materials were introduced in the 1970s, driven by concern that rigid metal cups could lead to scalp trauma on the infant, and single-use instruments followed in the 1990s, catalysed by moves to reduce transmissible infection. It adds that much of this evidence is circumstantial.

    Applies to Mixed recipients Women having an operative vaginal birth with a vacuum extractor, and their babies (engineering review 2020; commentary 2026)

    Certainty method
    Not assessed
    Limitations
    A historical account by the review authors; the claim about circumstantial evidence is theirs and is not tested here.
    Last checked
    2026-11-19
    Next evidence check due
    Not scheduled
    Sources and citations (3)
    1. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      Design evolution of VAD devices, paragraph 4, sentence 1
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    2. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      Design evolution of VAD devices, paragraph 5, sentence 1
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    3. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      Design evolution of VAD devices, paragraph 6, sentence 3
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
  • Description Evidence synthesis Certainty not assessed

    A 2020 engineering review describes a vacuum assisted delivery device as a suction cup placed on the baby's scalp, with negative pressure applied by a manual or electric pump. It reports that, after more than 50 years in clinical practice, these devices remain a mainstay in physically assisting birth and are sometimes preferred over forceps for ease of use and reduced maternal morbidity.

    Applies to Mixed recipients Women having an operative vaginal birth with a vacuum extractor, and their babies (engineering review 2020; commentary 2026)

    Certainty method
    Not assessed
    Limitations
    General statements in a review that cites works the atlas did not read. The atlas gives no indication, technique or advice.
    Last checked
    2026-11-19
    Next evidence check due
    Not scheduled
    Sources and citations (2)
    1. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      Introduction, paragraph 8, sentence 2
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    2. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      Abstract, paragraph 1, sentence 2
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
  • Description Evidence synthesis Certainty not assessed

    The 2020 review says the technical literature on vacuum assisted delivery devices is scarce, disparate and often difficult to source, that there is minimal evidence to inform device design or clinical use, and that there is an urgent need to evaluate the performance of these devices. The 2026 commentary reports a review of randomised trials in which sonographic knowledge of fetal head position before operative vaginal birth did not appear to reduce the incidence of failed procedures. It also proposes an ultrasound-based method and says that proposal requires prospective validation through randomised controlled trials. The atlas does not describe that method.

    Applies to Mixed recipients Women having an operative vaginal birth with a vacuum extractor, and their babies (engineering review 2020; commentary 2026)

    Certainty method
    Not assessed
    Limitations
    Statements by the review authors about the state of the evidence. The commentary's method is a proposal, not a tested practice. Certainty is not assessed here.
    Last checked
    2026-11-19
    Next evidence check due
    Not scheduled
    Sources and citations (4)
    1. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      Introduction, paragraph 9, sentence 3
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    2. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      Conclusion, paragraph 2, sentence 3
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    3. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      1. Introduction, paragraph 9, sentence 2
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    4. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      Abstract, paragraph 1, sentence 9
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Pregnancy, lactation and children

The claims about this product whose clinical context is a pregnancy, breastfeeding or a newborn, infant or child, grouped by that context. Each claim is also in Claims and evidence. A group with no claim is not shown, and an empty group does not mean the medicine is safe or unsafe there.

In newborns, infants and children 1

Claims whose context is a newborn, an infant or a child.

  • Safety Evidence synthesis Certainty not assessed

    Reviews report scalp and head injuries in babies after vacuum birth. The 2026 commentary lists cephalohematoma and intracranial hemorrhage among the complications of vacuum extraction and says that, compared with forceps, vacuum extraction carries a higher risk of neonatal scalp injury. The 2020 review gives subgaleal haematomas in approximately 6 in 10,000 vacuum deliveries, and the commentary cites a retrospective cohort study in which cup detachment went with higher rates of subgaleal hematoma (8.9% compared with 3.5%).

    Applies to Newborn Babies born with a vacuum extractor (reviews 2020 and 2026)

    Population, setting and follow-up
    • Babies delivered with a vacuum cup on the scalp, as described by the reviews. Figures are background statements from other studies the atlas has not read.
    • Hospital labour wards.
    • Not stated in the source
    • Birth and the first days after birth; the sources give no age band
    • Gestational age Not reported
    • Postnatal age Not reported
    Follow-up Not applicable (literature review)
    Certainty method
    Not assessed
    Limitations
    Background statements that cite studies the atlas did not read; the figures come from different populations and definitions and are not combined. Certainty is not assessed here.
    Last checked
    2026-11-19
    Next evidence check due
    Not scheduled
    Sources and citations (5)
    1. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      Abstract, paragraph 1, sentence 1
      How it applies
      Passage in the source that backs the claim.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    2. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 1, sentence 3
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    3. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 1, sentence 2
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    4. Supports An engineering perspective of vacuum assisted delivery devices in obstetrics: A review

      Publication · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used. · PMCID: PMC7780266 · PMID: 32928047 · DOI: 10.1177/0954411920956467

      Locator
      Clinical use of VAD systems, paragraph 6, sentence 4
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    5. Supports Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method

      Publication · Diagnostics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas. · PMCID: PMC13024969 · PMID: 41897680 · DOI: 10.3390/diagnostics16060946

      Locator
      1. Introduction, paragraph 5, sentence 2
      How it applies
      Background statement in the source that cites works the atlas did not read.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Record details

Record id
maternal:vacuum-extractor-devices
Content hash