  "release_id": "8f5d5a5ed7ba4f08",
  "id": "maternal:vacuum-extractor-devices",
  "owner": "maternal",
  "kind": "product",
  "slug": "vacuum-extractor-devices",
  "name": "Vacuum extractor devices",
  "aliases": [
    "Vacuum-assisted delivery devices",
    "Fetal vacuum extractors",
    "Vacuum cups for assisted birth"
  ],
  "atlases": [
    "maternal"
  ],
  "summary_plain": "A vacuum extractor is a suction cup device used to help with delivery. US federal rules identify the fetal vacuum extractor as a device that applies traction to the fetal head through a suction cup attached to the scalp and place the generic type in Class II. Reviews report that vacuum extraction carries a lower risk of maternal perineal trauma than forceps but higher failure rates and more scalp injury in babies, that soft and rigid cups trade failure against scalp injury, and that the evidence behind device design is thin. This page describes the device type, not any brand, and gives no advice on use.",
  "summary_technical": "Product, subtype device; a generic device type, not a single brand or model. FDA product code HDB (Extractor, Vacuum, Fetal), 21 CFR 884.4340, device class 2 (openFDA device classification record fetched 2026-11-19; eCFR text for 2026-11-01). Two open-access reviews were read: a 2020 engineering review (PMC7780266, CC BY 4.0) and a 2026 expert commentary that proposes an ultrasound method (PMC13024969, CC BY 4.0). Their statements about other studies cite works not read. No manufacturer, brand or 510(k) summary was read, so no other product record is linked. The operative vaginal birth record holds the care-pathway claims and is linked, not repeated. The commentary's proposed method and any technique, traction, timing or gestational-age rules are left out.",
  "editorial_state": "draft",
  "last_substantive_edit": "2026-11-19",
  "last_evidence_check": "2026-11-19",
  "next_review_due": "2027-05-19",
  "identifiers": [
    {
      "scheme": "fda-product-code",
      "value": "HDB",
      "normalized_value": "HDB",
      "match": "broad",
      "version": null,
      "label": null,
      "from_source": false
    },
    {
      "scheme": "cfr",
      "value": "21 CFR 884.4340",
      "normalized_value": "21 CFR 884.4340",
      "match": "broad",
      "version": null,
      "label": null,
      "from_source": false
    }
  ],
  "navigation": {
    "maternal": {
      "life-stage": [
        "childbirth"
      ],
      "care-area": [
        "labour-and-birth"
      ]
    }
  },
  "payload": {
    "subtype": "device",
    "model_or_formulation": "Fetal vacuum extractor as a generic device type (FDA product code HDB, 21 CFR 884.4340); no single brand or model",
    "version": "Regulation text as returned by the eCFR for 2026-11-01; classification record as fetched on 2026-11-19",
    "intended_use_snapshots": [
      "maternal:ecfr-21-cfr-884-4340-2026-11-19",
      "maternal:openfda-classification-vacuum-extractor-2026-11-19",
      "maternal:pmc-pmc7780266-2026-11-19",
      "maternal:pmc-pmc13024969-2026-11-19"
    ],
    "registry": null
  },
  "content_digest": "2349312166dfea471a882195f56bf07f38774d2b465e84977561c31d23d54eb2",
  "review": {
    "content_digest": "2349312166dfea471a882195f56bf07f38774d2b465e84977561c31d23d54eb2",
    "current": [],
    "conflicting": [],
    "stale": [],
    "inactive": []
  },
  "claims": [
    {
      "release_id": "8f5d5a5ed7ba4f08",
      "id": "maternal:claim-w47b-vac-babies",
      "owner": "maternal",
      "subject_entity_id": "maternal:vacuum-extractor-devices",
      "category": "safety",
      "statement": "Reviews report scalp and head injuries in babies after vacuum birth. The 2026 commentary lists cephalohematoma and intracranial hemorrhage among the complications of vacuum extraction and says that, compared with forceps, vacuum extraction carries a higher risk of neonatal scalp injury. The 2020 review gives subgaleal haematomas in approximately 6 in 10,000 vacuum deliveries, and the commentary cites a retrospective cohort study in which cup detachment went with higher rates of subgaleal hematoma (8.9% compared with 3.5%).",
      "context": {
        "id": "maternal:ctx-w47b-vac-babies",
        "label": "Babies born with a vacuum extractor (reviews 2020 and 2026)",
        "recipient": "newborn",
        "population": "Babies delivered with a vacuum cup on the scalp, as described by the reviews. Figures are background statements from other studies the atlas has not read.",
        "care_setting": "Hospital labour wards.",
        "geography": "Not stated in the source",
        "life_stage_note": "Birth and the first days after birth; the sources give no age band",
        "life_stage_terms": {
          "maternal": [
            "childbirth",
            "newborn"
          ]
        },
        "gestational_age_min_days": null,
        "gestational_age_max_days": null,
        "gestational_age_basis": null,
        "postnatal_age_min_days": null,
        "postnatal_age_max_days": null,
        "gestational_age_status": null,
        "postnatal_age_status": null,
        "followup_description": "Not applicable (literature review)",
        "eligibility": {
          "inclusion": [
            "Babies delivered with a vacuum extractor"
          ],
          "exclusion": []
        }
      },
      "evidence_stage": "synthesis",
      "certainty": "not_assessed",
      "certainty_method": null,
      "limitations": "Background statements that cite studies the atlas did not read; the figures come from different populations and definitions and are not combined. Certainty is not assessed here.",
      "editorial_state": "draft",
      "checked_at": "2026-11-19",
      "next_review_due": null,
      "valid_from": null,
      "valid_to": null,
      "citations": [
        {
          "evidence_role": "supports",
          "locator": "Abstract, paragraph 1, sentence 1",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 1, sentence 3",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 1, sentence 2",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "Clinical use of VAD systems, paragraph 6, sentence 4",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc7780266-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:25Z",
            "content_hash": "3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc7780266",
            "source_type": "publication",
            "title": "An engineering perspective of vacuum assisted delivery devices in obstetrics: A review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7780266/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC7780266",
                "normalized_value": "PMC7780266",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "32928047",
                "normalized_value": "32928047",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1177/0954411920956467",
                "normalized_value": "10.1177/0954411920956467",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC7780266.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "1. Introduction, paragraph 5, sentence 2",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        }
      ],
      "review": {
        "content_digest": "8dfbcfae491d4d984b3c1e8532f20814850991a12d1ce78145e715721d0bf3f3",
        "current": [],
        "conflicting": [],
        "stale": [],
        "inactive": []
      },
      "api_path": "api/v1/claims/maternal--claim-w47b-vac-babies.json"
    },
    {
      "release_id": "8f5d5a5ed7ba4f08",
      "id": "maternal:claim-w47b-vac-cups",
      "owner": "maternal",
      "subject_entity_id": "maternal:vacuum-extractor-devices",
      "category": "effect",
      "statement": "The 2026 commentary reports that historical randomised trials found soft cups to have higher failure and detachment rates than rigid or metal cups, although with fewer scalp injuries. It also reports a comparison in which one cup design had a significantly higher failure rate than conventional vacuum cups (30.1% compared with 19.2%; relative risk 1.58, 95% CI 1.10 to 2.24), and says that randomised and pragmatic trials suggest severe neonatal outcomes remain broadly comparable between disposable and metal devices. The 2020 review adds that unintentional cup detachments are the most prevalent clinical adverse event with these devices.",
      "context": {
        "id": "maternal:ctx-w47b-vac-devices",
        "label": "Women having an operative vaginal birth with a vacuum extractor, and their babies (engineering review 2020; commentary 2026)",
        "recipient": "mixed",
        "population": "Women having a vacuum-assisted birth and the babies whose scalp the cup is placed on, as described in an engineering review and an expert commentary. Neither is a study population.",
        "care_setting": "Hospital labour wards and delivery rooms, where the reviews place instrumental birth.",
        "geography": "UK and US usage figures are quoted in the sources; not itemised here.",
        "life_stage_note": "Second stage of labour",
        "life_stage_terms": {
          "maternal": [
            "childbirth"
          ]
        },
        "gestational_age_min_days": null,
        "gestational_age_max_days": null,
        "gestational_age_basis": null,
        "postnatal_age_min_days": null,
        "postnatal_age_max_days": null,
        "gestational_age_status": null,
        "postnatal_age_status": null,
        "followup_description": "Not applicable (literature review)",
        "eligibility": {
          "inclusion": [
            "Women and babies in vacuum-assisted vaginal birth, as described in the two reviews"
          ],
          "exclusion": []
        }
      },
      "evidence_stage": "synthesis",
      "certainty": "not_assessed",
      "certainty_method": null,
      "limitations": "A second-hand summary of trials the atlas did not read; no cup model is named here. Certainty is not assessed here.",
      "editorial_state": "draft",
      "checked_at": "2026-11-19",
      "next_review_due": null,
      "valid_from": null,
      "valid_to": null,
      "citations": [
        {
          "evidence_role": "supports",
          "locator": "3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 2, sentence 2",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 2, sentence 4",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 2, sentence 6",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "VAD mechanics & performance, paragraph 5, sentence 1",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc7780266-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:25Z",
            "content_hash": "3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc7780266",
            "source_type": "publication",
            "title": "An engineering perspective of vacuum assisted delivery devices in obstetrics: A review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7780266/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC7780266",
                "normalized_value": "PMC7780266",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "32928047",
                "normalized_value": "32928047",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1177/0954411920956467",
                "normalized_value": "10.1177/0954411920956467",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC7780266.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        }
      ],
      "review": {
        "content_digest": "299b5ccfefcaa62f648d8e2e752710e7c7c1f91ffb1c1730a1cd2a2009aed2f5",
        "current": [],
        "conflicting": [],
        "stale": [],
        "inactive": []
      },
      "api_path": "api/v1/claims/maternal--claim-w47b-vac-cups.json"
    },
    {
      "release_id": "8f5d5a5ed7ba4f08",
      "id": "maternal:claim-w47b-vac-design-history",
      "owner": "maternal",
      "subject_entity_id": "maternal:vacuum-extractor-devices",
      "category": "descriptive",
      "statement": "The 2020 review traces how the devices changed: pliable cups made from elastomeric materials were introduced in the 1970s, driven by concern that rigid metal cups could lead to scalp trauma on the infant, and single-use instruments followed in the 1990s, catalysed by moves to reduce transmissible infection. It adds that much of this evidence is circumstantial.",
      "context": {
        "id": "maternal:ctx-w47b-vac-devices",
        "label": "Women having an operative vaginal birth with a vacuum extractor, and their babies (engineering review 2020; commentary 2026)",
        "recipient": "mixed",
        "population": "Women having a vacuum-assisted birth and the babies whose scalp the cup is placed on, as described in an engineering review and an expert commentary. Neither is a study population.",
        "care_setting": "Hospital labour wards and delivery rooms, where the reviews place instrumental birth.",
        "geography": "UK and US usage figures are quoted in the sources; not itemised here.",
        "life_stage_note": "Second stage of labour",
        "life_stage_terms": {
          "maternal": [
            "childbirth"
          ]
        },
        "gestational_age_min_days": null,
        "gestational_age_max_days": null,
        "gestational_age_basis": null,
        "postnatal_age_min_days": null,
        "postnatal_age_max_days": null,
        "gestational_age_status": null,
        "postnatal_age_status": null,
        "followup_description": "Not applicable (literature review)",
        "eligibility": {
          "inclusion": [
            "Women and babies in vacuum-assisted vaginal birth, as described in the two reviews"
          ],
          "exclusion": []
        }
      },
      "evidence_stage": "synthesis",
      "certainty": "not_assessed",
      "certainty_method": null,
      "limitations": "A historical account by the review authors; the claim about circumstantial evidence is theirs and is not tested here.",
      "editorial_state": "draft",
      "checked_at": "2026-11-19",
      "next_review_due": null,
      "valid_from": null,
      "valid_to": null,
      "citations": [
        {
          "evidence_role": "supports",
          "locator": "Design evolution of VAD devices, paragraph 4, sentence 1",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc7780266-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:25Z",
            "content_hash": "3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc7780266",
            "source_type": "publication",
            "title": "An engineering perspective of vacuum assisted delivery devices in obstetrics: A review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7780266/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC7780266",
                "normalized_value": "PMC7780266",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "32928047",
                "normalized_value": "32928047",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1177/0954411920956467",
                "normalized_value": "10.1177/0954411920956467",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC7780266.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "Design evolution of VAD devices, paragraph 5, sentence 1",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc7780266-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:25Z",
            "content_hash": "3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc7780266",
            "source_type": "publication",
            "title": "An engineering perspective of vacuum assisted delivery devices in obstetrics: A review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7780266/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC7780266",
                "normalized_value": "PMC7780266",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "32928047",
                "normalized_value": "32928047",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1177/0954411920956467",
                "normalized_value": "10.1177/0954411920956467",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC7780266.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "Design evolution of VAD devices, paragraph 6, sentence 3",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc7780266-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:25Z",
            "content_hash": "3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc7780266",
            "source_type": "publication",
            "title": "An engineering perspective of vacuum assisted delivery devices in obstetrics: A review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7780266/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC7780266",
                "normalized_value": "PMC7780266",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "32928047",
                "normalized_value": "32928047",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1177/0954411920956467",
                "normalized_value": "10.1177/0954411920956467",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC7780266.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        }
      ],
      "review": {
        "content_digest": "07a64833b6df788dd0865ba5788ef388a9d710f39b3284298d165fe26ebca142",
        "current": [],
        "conflicting": [],
        "stale": [],
        "inactive": []
      },
      "api_path": "api/v1/claims/maternal--claim-w47b-vac-design-history.json"
    },
    {
      "release_id": "8f5d5a5ed7ba4f08",
      "id": "maternal:claim-w47b-vac-device",
      "owner": "maternal",
      "subject_entity_id": "maternal:vacuum-extractor-devices",
      "category": "descriptive",
      "statement": "A 2020 engineering review describes a vacuum assisted delivery device as a suction cup placed on the baby's scalp, with negative pressure applied by a manual or electric pump. It reports that, after more than 50 years in clinical practice, these devices remain a mainstay in physically assisting birth and are sometimes preferred over forceps for ease of use and reduced maternal morbidity.",
      "context": {
        "id": "maternal:ctx-w47b-vac-devices",
        "label": "Women having an operative vaginal birth with a vacuum extractor, and their babies (engineering review 2020; commentary 2026)",
        "recipient": "mixed",
        "population": "Women having a vacuum-assisted birth and the babies whose scalp the cup is placed on, as described in an engineering review and an expert commentary. Neither is a study population.",
        "care_setting": "Hospital labour wards and delivery rooms, where the reviews place instrumental birth.",
        "geography": "UK and US usage figures are quoted in the sources; not itemised here.",
        "life_stage_note": "Second stage of labour",
        "life_stage_terms": {
          "maternal": [
            "childbirth"
          ]
        },
        "gestational_age_min_days": null,
        "gestational_age_max_days": null,
        "gestational_age_basis": null,
        "postnatal_age_min_days": null,
        "postnatal_age_max_days": null,
        "gestational_age_status": null,
        "postnatal_age_status": null,
        "followup_description": "Not applicable (literature review)",
        "eligibility": {
          "inclusion": [
            "Women and babies in vacuum-assisted vaginal birth, as described in the two reviews"
          ],
          "exclusion": []
        }
      },
      "evidence_stage": "synthesis",
      "certainty": "not_assessed",
      "certainty_method": null,
      "limitations": "General statements in a review that cites works the atlas did not read. The atlas gives no indication, technique or advice.",
      "editorial_state": "draft",
      "checked_at": "2026-11-19",
      "next_review_due": null,
      "valid_from": null,
      "valid_to": null,
      "citations": [
        {
          "evidence_role": "supports",
          "locator": "Introduction, paragraph 8, sentence 2",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc7780266-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:25Z",
            "content_hash": "3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc7780266",
            "source_type": "publication",
            "title": "An engineering perspective of vacuum assisted delivery devices in obstetrics: A review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7780266/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC7780266",
                "normalized_value": "PMC7780266",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "32928047",
                "normalized_value": "32928047",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1177/0954411920956467",
                "normalized_value": "10.1177/0954411920956467",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC7780266.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "Abstract, paragraph 1, sentence 2",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc7780266-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:25Z",
            "content_hash": "3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc7780266",
            "source_type": "publication",
            "title": "An engineering perspective of vacuum assisted delivery devices in obstetrics: A review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7780266/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC7780266",
                "normalized_value": "PMC7780266",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "32928047",
                "normalized_value": "32928047",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1177/0954411920956467",
                "normalized_value": "10.1177/0954411920956467",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC7780266.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        }
      ],
      "review": {
        "content_digest": "3c7c0860df4e7c6e65e211721c1a77502a2b1fd8b202c5621743a3e7b919c72c",
        "current": [],
        "conflicting": [],
        "stale": [],
        "inactive": []
      },
      "api_path": "api/v1/claims/maternal--claim-w47b-vac-device.json"
    },
    {
      "release_id": "8f5d5a5ed7ba4f08",
      "id": "maternal:claim-w47b-vac-evidence",
      "owner": "maternal",
      "subject_entity_id": "maternal:vacuum-extractor-devices",
      "category": "descriptive",
      "statement": "The 2020 review says the technical literature on vacuum assisted delivery devices is scarce, disparate and often difficult to source, that there is minimal evidence to inform device design or clinical use, and that there is an urgent need to evaluate the performance of these devices. The 2026 commentary reports a review of randomised trials in which sonographic knowledge of fetal head position before operative vaginal birth did not appear to reduce the incidence of failed procedures. It also proposes an ultrasound-based method and says that proposal requires prospective validation through randomised controlled trials. The atlas does not describe that method.",
      "context": {
        "id": "maternal:ctx-w47b-vac-devices",
        "label": "Women having an operative vaginal birth with a vacuum extractor, and their babies (engineering review 2020; commentary 2026)",
        "recipient": "mixed",
        "population": "Women having a vacuum-assisted birth and the babies whose scalp the cup is placed on, as described in an engineering review and an expert commentary. Neither is a study population.",
        "care_setting": "Hospital labour wards and delivery rooms, where the reviews place instrumental birth.",
        "geography": "UK and US usage figures are quoted in the sources; not itemised here.",
        "life_stage_note": "Second stage of labour",
        "life_stage_terms": {
          "maternal": [
            "childbirth"
          ]
        },
        "gestational_age_min_days": null,
        "gestational_age_max_days": null,
        "gestational_age_basis": null,
        "postnatal_age_min_days": null,
        "postnatal_age_max_days": null,
        "gestational_age_status": null,
        "postnatal_age_status": null,
        "followup_description": "Not applicable (literature review)",
        "eligibility": {
          "inclusion": [
            "Women and babies in vacuum-assisted vaginal birth, as described in the two reviews"
          ],
          "exclusion": []
        }
      },
      "evidence_stage": "synthesis",
      "certainty": "not_assessed",
      "certainty_method": null,
      "limitations": "Statements by the review authors about the state of the evidence. The commentary's method is a proposal, not a tested practice. Certainty is not assessed here.",
      "editorial_state": "draft",
      "checked_at": "2026-11-19",
      "next_review_due": null,
      "valid_from": null,
      "valid_to": null,
      "citations": [
        {
          "evidence_role": "supports",
          "locator": "Introduction, paragraph 9, sentence 3",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc7780266-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:25Z",
            "content_hash": "3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc7780266",
            "source_type": "publication",
            "title": "An engineering perspective of vacuum assisted delivery devices in obstetrics: A review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7780266/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC7780266",
                "normalized_value": "PMC7780266",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "32928047",
                "normalized_value": "32928047",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1177/0954411920956467",
                "normalized_value": "10.1177/0954411920956467",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC7780266.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "Conclusion, paragraph 2, sentence 3",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc7780266-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:25Z",
            "content_hash": "3fa8bd408d19470962b39f8526f97760f4c06bf240e0ca82c0b8a642bd7af839",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc7780266",
            "source_type": "publication",
            "title": "An engineering perspective of vacuum assisted delivery devices in obstetrics: A review",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC7780266/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC7780266",
                "normalized_value": "PMC7780266",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "32928047",
                "normalized_value": "32928047",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.1177/0954411920956467",
                "normalized_value": "10.1177/0954411920956467",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2020). An engineering review. Used: the abstract, the design history, the adverse-event passage and the conclusion. Technique detail is not used.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC7780266.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "1. Introduction, paragraph 9, sentence 2",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "Abstract, paragraph 1, sentence 9",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        }
      ],
      "review": {
        "content_digest": "de1b28fd9e136e9bc53f688db1c4b7d3a07f57de6797fddfa35f7d43fbe5d79e",
        "current": [],
        "conflicting": [],
        "stale": [],
        "inactive": []
      },
      "api_path": "api/v1/claims/maternal--claim-w47b-vac-evidence.json"
    },
    {
      "release_id": "8f5d5a5ed7ba4f08",
      "id": "maternal:claim-w47b-vac-maternal",
      "owner": "maternal",
      "subject_entity_id": "maternal:vacuum-extractor-devices",
      "category": "effect",
      "statement": "A 2026 expert commentary says that vacuum extraction has gained popularity because of a lower risk of maternal perineal trauma than with forceps, and, citing randomised evidence summarised by Cochrane reviews, that forceps are more likely to achieve vaginal birth than vacuum extraction but carry higher rates of severe maternal perineal trauma.",
      "context": {
        "id": "maternal:ctx-w47b-vac-women",
        "label": "Women having an operative vaginal birth with a vacuum extractor or forceps (2026 commentary)",
        "recipient": "maternal",
        "population": "Women having an instrumental vaginal birth; the commentary summarises Cochrane review findings on perineal trauma and success of vaginal birth for vacuum extraction compared with forceps.",
        "care_setting": "Hospital labour wards.",
        "geography": "Not stated in the source",
        "life_stage_note": "Second stage of labour",
        "life_stage_terms": {
          "maternal": [
            "childbirth"
          ]
        },
        "gestational_age_min_days": null,
        "gestational_age_max_days": null,
        "gestational_age_basis": null,
        "postnatal_age_min_days": null,
        "postnatal_age_max_days": null,
        "gestational_age_status": null,
        "postnatal_age_status": null,
        "followup_description": "Not applicable (literature commentary)",
        "eligibility": {
          "inclusion": [
            "Women having a vacuum or forceps birth in the trials the commentary summarises"
          ],
          "exclusion": []
        }
      },
      "evidence_stage": "synthesis",
      "certainty": "not_assessed",
      "certainty_method": null,
      "limitations": "The commentary summarises reviews and trials it does not reproduce; the atlas did not read them. No figures are given in the passage. Certainty is not assessed here.",
      "editorial_state": "draft",
      "checked_at": "2026-11-19",
      "next_review_due": null,
      "valid_from": null,
      "valid_to": null,
      "citations": [
        {
          "evidence_role": "supports",
          "locator": "1. Introduction, paragraph 1, sentence 5",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "3. Discussion, 3.1. Instrument Selection and Device Considerations, paragraph 1, sentence 2",
          "applicability_note": "Background statement in the source that cites works the atlas did not read.",
          "snapshot": {
            "id": "maternal:pmc-pmc13024969-2026-11-19",
            "retrieved_at": "2026-11-19T01:42:26Z",
            "content_hash": "8b2e03d1dabfc41a34ca899f60d1dadad278c80683a31ff8d61a00b4df0423f9",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:pmc-pmc13024969",
            "source_type": "publication",
            "title": "Intrapartum Ultrasound in Vacuum Operative Delivery: A Comprehensive Review and Proposal of the Novel Ultrasound Flexion Point Method",
            "canonical_url": "https://pmc.ncbi.nlm.nih.gov/articles/PMC13024969/",
            "identifiers": [
              {
                "scheme": "pmcid",
                "value": "PMC13024969",
                "normalized_value": "PMC13024969",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "pmid",
                "value": "41897680",
                "normalized_value": "41897680",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              },
              {
                "scheme": "doi",
                "value": "10.3390/diagnostics16060946",
                "normalized_value": "10.3390/diagnostics16060946",
                "match": "exact",
                "version": null,
                "label": null,
                "from_source": false
              }
            ],
            "publication_date": null,
            "publisher": "Diagnostics",
            "edition": "PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). An expert commentary and technical proposal. Used: the abstract, the introduction and the instrument-selection discussion. The proposed ultrasound method is not described in the atlas.",
            "reuse_basis": "PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered at research/snapshots/w47b-pmc-PMC13024969.xml, which the licence allows with attribution. Short quotations under 25 words.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        }
      ],
      "review": {
        "content_digest": "ede086a117e28cfe52ea532a5c81bb0f6e6b4b4231048b86a64cc585d2ca9ef9",
        "current": [],
        "conflicting": [],
        "stale": [],
        "inactive": []
      },
      "api_path": "api/v1/claims/maternal--claim-w47b-vac-maternal.json"
    },
    {
      "release_id": "8f5d5a5ed7ba4f08",
      "id": "maternal:claim-w47b-vac-regulatory",
      "owner": "maternal",
      "subject_entity_id": "maternal:vacuum-extractor-devices",
      "category": "regulatory",
      "statement": "Title 21 of the Code of Federal Regulations, section 884.4340 (eCFR text returned for 1 November 2026), identifies a fetal vacuum extractor as a device used to facilitate delivery, applying traction to the fetal head in the birth canal by a suction cup attached to the scalp and powered by an external vacuum source, and classifies the generic type as Class II (performance standards). The openFDA classification record for the device lists the product code HDB, the name Extractor, Vacuum, Fetal, and device class 2.",
      "context": {
        "id": "maternal:ctx-w47b-vac-regulatory",
        "label": "US federal device rules for fetal vacuum extractors, not a study population",
        "recipient": "not_applicable",
        "population": "No population. The text identifies and classifies a generic type of medical device in United States rules.",
        "care_setting": "Not applicable.",
        "geography": "United States.",
        "life_stage_note": "Not applicable",
        "life_stage_terms": {
          "maternal": [
            "childbirth"
          ]
        },
        "gestational_age_min_days": null,
        "gestational_age_max_days": null,
        "gestational_age_basis": null,
        "postnatal_age_min_days": null,
        "postnatal_age_max_days": null,
        "gestational_age_status": null,
        "postnatal_age_status": null,
        "followup_description": "Not applicable (regulatory context).",
        "eligibility": {
          "inclusion": [],
          "exclusion": []
        }
      },
      "evidence_stage": "not_applicable",
      "certainty": "not_assessed",
      "certainty_method": null,
      "limitations": "A federal classification of a generic device type, not a statement about any brand or about safety or benefit in use. openFDA states that its data are unvalidated and not for medical decisions. The record lists many 510(k) numbers; none was read. The eCFR is an editorial compilation, not the legal edition.",
      "editorial_state": "draft",
      "checked_at": "2026-11-19",
      "next_review_due": null,
      "valid_from": null,
      "valid_to": null,
      "citations": [
        {
          "evidence_role": "supports",
          "locator": "884.4340 (a) Identification, sentence 1",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:ecfr-21-cfr-884-4340-2026-11-19",
            "retrieved_at": "2026-11-19T01:52:55Z",
            "content_hash": "c3eec01f4ee3d562b635c2ec7e10b2799eea5be930268eb96a6123ea87d5b24d",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:ecfr-21-cfr-884-4340",
            "source_type": "regulator",
            "title": "21 CFR 884.4340 Fetal vacuum extractor (eCFR)",
            "canonical_url": "https://www.ecfr.gov/api/versioner/v1/full/2026-11-01/title-21.xml?part=884&section=884.4340",
            "identifiers": [],
            "publication_date": null,
            "publisher": "Office of the Federal Register and U.S. Government Publishing Office (eCFR)",
            "edition": "eCFR section text as returned by the versioner API for 2026-11-01. The first request, made without a gzip encoding header, was not accepted; the committed file is the decompressed response to the second request.",
            "reuse_basis": "Text of a US federal regulation. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c, read on 2026-10-14 for maternal:ecfr-21-cfr-880-5690 and not fetched again in this session) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. The eCFR is an editorial compilation and is not the legal edition of the CFR. The raw file is committed at research/snapshots/w47b-ecfr-884-4340-gz.xml.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "884.4340 (a) Identification, sentence 2, part 1",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:ecfr-21-cfr-884-4340-2026-11-19",
            "retrieved_at": "2026-11-19T01:52:55Z",
            "content_hash": "c3eec01f4ee3d562b635c2ec7e10b2799eea5be930268eb96a6123ea87d5b24d",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:ecfr-21-cfr-884-4340",
            "source_type": "regulator",
            "title": "21 CFR 884.4340 Fetal vacuum extractor (eCFR)",
            "canonical_url": "https://www.ecfr.gov/api/versioner/v1/full/2026-11-01/title-21.xml?part=884&section=884.4340",
            "identifiers": [],
            "publication_date": null,
            "publisher": "Office of the Federal Register and U.S. Government Publishing Office (eCFR)",
            "edition": "eCFR section text as returned by the versioner API for 2026-11-01. The first request, made without a gzip encoding header, was not accepted; the committed file is the decompressed response to the second request.",
            "reuse_basis": "Text of a US federal regulation. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c, read on 2026-10-14 for maternal:ecfr-21-cfr-880-5690 and not fetched again in this session) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. The eCFR is an editorial compilation and is not the legal edition of the CFR. The raw file is committed at research/snapshots/w47b-ecfr-884-4340-gz.xml.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "884.4340 (a) Identification, sentence 2, part 2",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:ecfr-21-cfr-884-4340-2026-11-19",
            "retrieved_at": "2026-11-19T01:52:55Z",
            "content_hash": "c3eec01f4ee3d562b635c2ec7e10b2799eea5be930268eb96a6123ea87d5b24d",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:ecfr-21-cfr-884-4340",
            "source_type": "regulator",
            "title": "21 CFR 884.4340 Fetal vacuum extractor (eCFR)",
            "canonical_url": "https://www.ecfr.gov/api/versioner/v1/full/2026-11-01/title-21.xml?part=884&section=884.4340",
            "identifiers": [],
            "publication_date": null,
            "publisher": "Office of the Federal Register and U.S. Government Publishing Office (eCFR)",
            "edition": "eCFR section text as returned by the versioner API for 2026-11-01. The first request, made without a gzip encoding header, was not accepted; the committed file is the decompressed response to the second request.",
            "reuse_basis": "Text of a US federal regulation. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c, read on 2026-10-14 for maternal:ecfr-21-cfr-880-5690 and not fetched again in this session) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. The eCFR is an editorial compilation and is not the legal edition of the CFR. The raw file is committed at research/snapshots/w47b-ecfr-884-4340-gz.xml.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "884.4340 (b) Classification",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:ecfr-21-cfr-884-4340-2026-11-19",
            "retrieved_at": "2026-11-19T01:52:55Z",
            "content_hash": "c3eec01f4ee3d562b635c2ec7e10b2799eea5be930268eb96a6123ea87d5b24d",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:ecfr-21-cfr-884-4340",
            "source_type": "regulator",
            "title": "21 CFR 884.4340 Fetal vacuum extractor (eCFR)",
            "canonical_url": "https://www.ecfr.gov/api/versioner/v1/full/2026-11-01/title-21.xml?part=884&section=884.4340",
            "identifiers": [],
            "publication_date": null,
            "publisher": "Office of the Federal Register and U.S. Government Publishing Office (eCFR)",
            "edition": "eCFR section text as returned by the versioner API for 2026-11-01. The first request, made without a gzip encoding header, was not accepted; the committed file is the decompressed response to the second request.",
            "reuse_basis": "Text of a US federal regulation. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c, read on 2026-10-14 for maternal:ecfr-21-cfr-880-5690 and not fetched again in this session) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. The eCFR is an editorial compilation and is not the legal edition of the CFR. The raw file is committed at research/snapshots/w47b-ecfr-884-4340-gz.xml.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "results[0].device_name",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:openfda-classification-vacuum-extractor-2026-11-19",
            "retrieved_at": "2026-11-19T01:52:34Z",
            "content_hash": "471215c51af1b0dce8833165dedaf40a89a49e19f5ae3fbf5ff38acbc0c2b07d",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:openfda-classification-vacuum-extractor",
            "source_type": "dataset",
            "title": "openFDA device classification records matching the device name vacuum extractor (product code HDB, Extractor, Vacuum, Fetal)",
            "canonical_url": "https://api.fda.gov/device/classification.json?search=device_name:%22vacuum%22+AND+device_name:%22extractor%22&limit=10",
            "identifiers": [],
            "publication_date": null,
            "publisher": "U.S. Food and Drug Administration (openFDA device classification endpoint)",
            "edition": "openFDA device classification search result fetched on 2026-11-19 (openFDA data last updated 2026-11-09). It holds one record: Extractor, Vacuum, Fetal (HDB).",
            "reuse_basis": "openFDA data is public domain under a Creative Commons CC0 1.0 Universal dedication unless noted (https://open.fda.gov/terms/, https://open.fda.gov/license/). The raw file is committed at research/snapshots/w47b-openfda-class-vacuum.json.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "results[0].product_code",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:openfda-classification-vacuum-extractor-2026-11-19",
            "retrieved_at": "2026-11-19T01:52:34Z",
            "content_hash": "471215c51af1b0dce8833165dedaf40a89a49e19f5ae3fbf5ff38acbc0c2b07d",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:openfda-classification-vacuum-extractor",
            "source_type": "dataset",
            "title": "openFDA device classification records matching the device name vacuum extractor (product code HDB, Extractor, Vacuum, Fetal)",
            "canonical_url": "https://api.fda.gov/device/classification.json?search=device_name:%22vacuum%22+AND+device_name:%22extractor%22&limit=10",
            "identifiers": [],
            "publication_date": null,
            "publisher": "U.S. Food and Drug Administration (openFDA device classification endpoint)",
            "edition": "openFDA device classification search result fetched on 2026-11-19 (openFDA data last updated 2026-11-09). It holds one record: Extractor, Vacuum, Fetal (HDB).",
            "reuse_basis": "openFDA data is public domain under a Creative Commons CC0 1.0 Universal dedication unless noted (https://open.fda.gov/terms/, https://open.fda.gov/license/). The raw file is committed at research/snapshots/w47b-openfda-class-vacuum.json.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "results[0].device_class",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:openfda-classification-vacuum-extractor-2026-11-19",
            "retrieved_at": "2026-11-19T01:52:34Z",
            "content_hash": "471215c51af1b0dce8833165dedaf40a89a49e19f5ae3fbf5ff38acbc0c2b07d",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:openfda-classification-vacuum-extractor",
            "source_type": "dataset",
            "title": "openFDA device classification records matching the device name vacuum extractor (product code HDB, Extractor, Vacuum, Fetal)",
            "canonical_url": "https://api.fda.gov/device/classification.json?search=device_name:%22vacuum%22+AND+device_name:%22extractor%22&limit=10",
            "identifiers": [],
            "publication_date": null,
            "publisher": "U.S. Food and Drug Administration (openFDA device classification endpoint)",
            "edition": "openFDA device classification search result fetched on 2026-11-19 (openFDA data last updated 2026-11-09). It holds one record: Extractor, Vacuum, Fetal (HDB).",
            "reuse_basis": "openFDA data is public domain under a Creative Commons CC0 1.0 Universal dedication unless noted (https://open.fda.gov/terms/, https://open.fda.gov/license/). The raw file is committed at research/snapshots/w47b-openfda-class-vacuum.json.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        },
        {
          "evidence_role": "supports",
          "locator": "results[0].regulation_number",
          "applicability_note": "Passage in the source that backs the claim.",
          "snapshot": {
            "id": "maternal:openfda-classification-vacuum-extractor-2026-11-19",
            "retrieved_at": "2026-11-19T01:52:34Z",
            "content_hash": "471215c51af1b0dce8833165dedaf40a89a49e19f5ae3fbf5ff38acbc0c2b07d",
            "source_effective_date": null,
            "public_archive_url": null,
            "source_state": "current"
          },
          "source": {
            "id": "maternal:openfda-classification-vacuum-extractor",
            "source_type": "dataset",
            "title": "openFDA device classification records matching the device name vacuum extractor (product code HDB, Extractor, Vacuum, Fetal)",
            "canonical_url": "https://api.fda.gov/device/classification.json?search=device_name:%22vacuum%22+AND+device_name:%22extractor%22&limit=10",
            "identifiers": [],
            "publication_date": null,
            "publisher": "U.S. Food and Drug Administration (openFDA device classification endpoint)",
            "edition": "openFDA device classification search result fetched on 2026-11-19 (openFDA data last updated 2026-11-09). It holds one record: Extractor, Vacuum, Fetal (HDB).",
            "reuse_basis": "openFDA data is public domain under a Creative Commons CC0 1.0 Universal dedication unless noted (https://open.fda.gov/terms/, https://open.fda.gov/license/). The raw file is committed at research/snapshots/w47b-openfda-class-vacuum.json.",
            "public_text": "quote",
            "replaced_by": null,
            "retirement_note": null
          }
        }
      ],
      "review": {
        "content_digest": "00926462d228a814d4b0c3dfa27dca536bc1636cd08a8b2c9fde29ce9acd8ba4",
        "current": [],
        "conflicting": [],
        "stale": [],
        "inactive": []
      },
      "api_path": "api/v1/claims/maternal--claim-w47b-vac-regulatory.json"
    }
  ],
  "decisions": [],
  "milestones": [],
  "relationships": {
    "outgoing": [
      {
        "predicate": "related_to",
        "label": "The birth procedure in which the device is used",
        "clinical_claim_not_fact": false,
        "family": "navigation",
        "other_entity_id": "maternal:operative-vaginal-birth",
        "other_entity_in_atlas": true,
        "claim_id": null,
        "evidence": null,
        "primary": false,
        "role": null,
        "valid_from": null,
        "valid_to": null
      },
      {
        "predicate": "related_to",
        "label": "Scalp injuries are among the reported risks to the baby",
        "clinical_claim_not_fact": false,
        "family": "navigation",
        "other_entity_id": "maternal:birth-injuries",
        "other_entity_in_atlas": true,
        "claim_id": null,
        "evidence": null,
        "primary": false,
        "role": null,
        "valid_from": null,
        "valid_to": null
      },
      {
        "predicate": "related_to",
        "label": "Maternal perineal trauma is compared between vacuum and forceps in the 2026 commentary",
        "clinical_claim_not_fact": false,
        "family": "navigation",
        "other_entity_id": "maternal:perineal-tear-and-obstetric-anal-sphincter-injury",
        "other_entity_in_atlas": true,
        "claim_id": null,
        "evidence": null,
        "primary": false,
        "role": null,
        "valid_from": null,
        "valid_to": null
      },
      {
        "predicate": "part_of",
        "label": "Filed under this front",
        "clinical_claim_not_fact": false,
        "family": "navigation",
        "other_entity_id": "maternal:front-procedures-and-birth-care",
        "other_entity_in_atlas": true,
        "claim_id": null,
        "evidence": null,
        "primary": true,
        "role": null,
        "valid_from": null,
        "valid_to": null
      }
    ],
    "incoming": []
  },
  "page_path": "products/vacuum-extractor-devices/",