sFlt-1/PlGF ratio
A blood test result for a pregnant woman: two proteins, sFlt-1 and placental growth factor (PlGF), are measured in the same sample, and the first is divided by the second. In the United States, the FDA clears one version as an aid for judging, within two weeks, the risk of pre-eclampsia with severe features (the FDA term) in women already in hospital with high blood pressure, and the FDA regulation for prognostic tests of this kind says they are not intended for diagnosis. The page describes this US use only.
Also called sFlt-1 to PlGF ratio · soluble fms-like tyrosine kinase-1 to placental growth factor ratio
- Biomarker
- In this atlas
Overview
Technical summary
The ratio of soluble fms-like tyrosine kinase-1 (sFlt-1) to placental growth factor (PlGF) measured by a matched pair of immunoassays, in human serum (Elecsys) or in serum or K2-EDTA plasma (KRYPTOR). Interpretation depends on the stated intended use. US: 21 CFR 862.1602 describes a prognostic aid device type for the development or progression of pre-eclampsia and says that device is not intended for diagnosis; the K241453 indication covers singleton pregnancies at 23+0 to 34+6/7 weeks hospitalized for a hypertensive disorder of pregnancy, with progression to pre-eclampsia with severe features within two weeks from testing. A cut-off printed for one use must not be applied to another use. This record gives no cut-off as a general rule.
What is measured
- Measure
- Ratio of the sFlt-1 concentration to the PlGF concentration in a single sample (serum for the Elecsys pair, serum or K2-EDTA plasma for the KRYPTOR pair), from two paired immunoassays.
- Assay context
- Laboratory immunoassays on an automated analyzer. Roche's K241453 510(k) Summary says values from other manufacturers' assays "may result in significantly different ratios" and that only the Elecsys sFlt-1 and Elecsys PlGF assays should be used to calculate the Elecsys ratio. Uses and cut-offs depend on the stated intended use and are kept in claims and contexts of their own.
Interpretation
Under 21 CFR 862.1602, FDA classifies a prognostic test for development or progression of pre-eclampsia as "an in vitro diagnostic device" indicated as an aid in the risk assessment for the development or progression of pre-eclampsia, and the regulation says "This device is not intended for diagnosis of any disease." The Elecsys sFlt-1 and PlGF system (K241453) is cleared under this regulation, and the KRYPTOR system (DEN220027) is described in its own claim. The labelling of the Elecsys sFlt-1 and PlGF test, cleared as K241453, applies the ratio to hospitalized women with a singleton pregnancy at 23+0 to 34+6/7 weeks and a hypertensive disorder of pregnancy, to judge whether pre-eclampsia with severe features will develop within two weeks from testing, with clinical assessment and routine laboratory testing. The regulation requires labelling to say a result is not to be used to aid the diagnosis of pre-eclampsia, or decisions about hospital discharge or pregnancy delivery. The cut-off of 38 that Roche's study validated belongs to this use.
Applies to Maternal Hospitalized for a hypertensive disorder of pregnancy, singleton pregnancy, 23 weeks 0 days to 34 weeks 6 days (US labelling of K241453)
Population, setting and follow-up
- Pregnant women with a singleton pregnancy, hospitalized for a hypertensive disorder of pregnancy (pre-eclampsia, chronic hypertension with or without superimposed pre-eclampsia, or gestational hypertension), at 23 weeks 0 days to 34 weeks 6 days.
- Hospital. The indication is for women hospitalized for the disorder.
- United States (FDA labelling)
- Pregnancy, 23 weeks 0 days to 34 weeks 6 days
- Gestational age 23 weeks 0 days to 34 weeks 6 days, measured at the time of measurement
- Postnatal age Not reported
- Certainty method
- Not assessed
- Limitations
- This is the US use only. A cut-off belongs to the stated use, outcome and gestational window it was validated for, so no threshold may be carried to another context. Performance figures are in their own claim and come from the submitter's study. This claim describes what the documents say. It does not say which use is clinically better.
- Last checked
- 2026-10-12
- Next evidence check due
- Not scheduled
Sources and citations (10)
-
Supports 21 CFR 862.1602, Prognostic test for development or progression of preeclampsia (eCFR)
- Locator
- (a) Identification, sentence 1, second part
- How it applies
- 21 CFR 862.1602: the device type is an in vitro diagnostic device.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
40d9dddc624d5ae8c365a5a4d95a64b105d43a43041133af9144573c4af440e1- Reuse basis
- Text of a US federal regulation, 2838 bytes, committed in the atlas repository. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. This basis rests on the GovInfo notice alone, as for the core copy of 21 CFR 870.1130.
-
Supports 21 CFR 862.1602, Prognostic test for development or progression of preeclampsia (eCFR)
- Locator
- (a) Identification, sentence 2
- How it applies
- 21 CFR 862.1602: the device type is an aid in the risk assessment for the development or progression of pre-eclampsia.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
40d9dddc624d5ae8c365a5a4d95a64b105d43a43041133af9144573c4af440e1- Reuse basis
- Text of a US federal regulation, 2838 bytes, committed in the atlas repository. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. This basis rests on the GovInfo notice alone, as for the core copy of 21 CFR 870.1130.
-
Supports 21 CFR 862.1602, Prognostic test for development or progression of preeclampsia (eCFR)
- Locator
- (a) Identification, sentence 3
- How it applies
- 21 CFR 862.1602: not intended for diagnosis of any disease.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
40d9dddc624d5ae8c365a5a4d95a64b105d43a43041133af9144573c4af440e1- Reuse basis
- Text of a US federal regulation, 2838 bytes, committed in the atlas repository. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. This basis rests on the GovInfo notice alone, as for the core copy of 21 CFR 870.1130.
-
Background 21 CFR 862.1602, Prognostic test for development or progression of preeclampsia (eCFR)
- Locator
- (b)(2)(ii) Limiting statements, lead-in
- How it applies
- The labelling of a device of this type must carry limiting statements.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
40d9dddc624d5ae8c365a5a4d95a64b105d43a43041133af9144573c4af440e1- Reuse basis
- Text of a US federal regulation, 2838 bytes, committed in the atlas repository. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. This basis rests on the GovInfo notice alone, as for the core copy of 21 CFR 870.1130.
-
Supports 21 CFR 862.1602, Prognostic test for development or progression of preeclampsia (eCFR)
- Locator
- (b)(2)(ii)(B)
- How it applies
- Limiting statement on diagnosis.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
40d9dddc624d5ae8c365a5a4d95a64b105d43a43041133af9144573c4af440e1- Reuse basis
- Text of a US federal regulation, 2838 bytes, committed in the atlas repository. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. This basis rests on the GovInfo notice alone, as for the core copy of 21 CFR 870.1130.
-
Supports 21 CFR 862.1602, Prognostic test for development or progression of preeclampsia (eCFR)
- Locator
- (b)(2)(ii)(C)
- How it applies
- Limiting statement on hospital discharge.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
40d9dddc624d5ae8c365a5a4d95a64b105d43a43041133af9144573c4af440e1- Reuse basis
- Text of a US federal regulation, 2838 bytes, committed in the atlas repository. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. This basis rests on the GovInfo notice alone, as for the core copy of 21 CFR 870.1130.
-
Supports 21 CFR 862.1602, Prognostic test for development or progression of preeclampsia (eCFR)
- Locator
- (b)(2)(ii)(D)
- How it applies
- Limiting statement on pregnancy delivery.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
40d9dddc624d5ae8c365a5a4d95a64b105d43a43041133af9144573c4af440e1- Reuse basis
- Text of a US federal regulation, 2838 bytes, committed in the atlas repository. The GovInfo Public Domain and Copyright Notice (sha256 d9e3a2f1cb4486ab4ecc4eff640f94f9a9bb8655ca71ff00694b236e7011ad1c) cites 17 U.S.C. 105, under which copyright protection is not available for any work of the United States Government. This basis rests on the GovInfo notice alone, as for the core copy of 21 CFR 870.1130.
-
Supports FDA 510(k) premarket notification K241453, Elecsys sFlt-1 and Elecsys PlGF (Roche Diagnostics)
- Locator
- Clearance letter, page 1, reference block
- How it applies
- K241453 carries regulation 21 CFR 862.1602 and product code QWH.
- Retrieved
- Source effective date
- 2025-02-07
- Source state
- Current
- Version fingerprint
edc99e5f8d778ceb857c5c649899e2ef4469ca6b919ee6e47f4e9a07b9662f00- Reuse basis
- The openFDA license page (sha256 7fda0041a24f8d7139a1781d4462ae39643a2ee6f3b0f079946c989a8e1982d2) says openFDA content and data are public domain under a CC0 1.0 dedication. The FDA website policies page (sha256 e7cf15d3edf28bd645ce47acd2a96bde8eafab0743981949df0a79019d59a2b2) says FDA website content is not copyrighted unless otherwise noted. The openFDA JSON is committed in the atlas repository; it holds the applicant's business contact name exactly as FDA publishes it. The 510(k) summary PDF is Roche's submission text released by FDA, so only short quotations are used and its bytes are not committed.
-
Supports FDA 510(k) premarket notification K241453, Elecsys sFlt-1 and Elecsys PlGF (Roche Diagnostics)
- Locator
- Indications for Use form
- How it applies
- The K241453 indication wording, in fragments. Roche's text as released by FDA; short quotation only.
- Retrieved
- Source effective date
- 2025-02-07
- Source state
- Current
- Version fingerprint
edc99e5f8d778ceb857c5c649899e2ef4469ca6b919ee6e47f4e9a07b9662f00- Reuse basis
- The openFDA license page (sha256 7fda0041a24f8d7139a1781d4462ae39643a2ee6f3b0f079946c989a8e1982d2) says openFDA content and data are public domain under a CC0 1.0 dedication. The FDA website policies page (sha256 e7cf15d3edf28bd645ce47acd2a96bde8eafab0743981949df0a79019d59a2b2) says FDA website content is not copyrighted unless otherwise noted. The openFDA JSON is committed in the atlas repository; it holds the applicant's business contact name exactly as FDA publishes it. The 510(k) summary PDF is Roche's submission text released by FDA, so only short quotations are used and its bytes are not committed.
-
Supports FDA 510(k) premarket notification K241453, Elecsys sFlt-1 and Elecsys PlGF (Roche Diagnostics)
- Locator
- 510(k) Summary, 5 Clinical performance evaluation, paragraph 1
- How it applies
- PRAECIS validated the cut-off of 38 for this use.
- Retrieved
- Source effective date
- 2025-02-07
- Source state
- Current
- Version fingerprint
edc99e5f8d778ceb857c5c649899e2ef4469ca6b919ee6e47f4e9a07b9662f00- Reuse basis
- The openFDA license page (sha256 7fda0041a24f8d7139a1781d4462ae39643a2ee6f3b0f079946c989a8e1982d2) says openFDA content and data are public domain under a CC0 1.0 dedication. The FDA website policies page (sha256 e7cf15d3edf28bd645ce47acd2a96bde8eafab0743981949df0a79019d59a2b2) says FDA website content is not copyrighted unless otherwise noted. The openFDA JSON is committed in the atlas repository; it holds the applicant's business contact name exactly as FDA publishes it. The 510(k) summary PDF is Roche's submission text released by FDA, so only short quotations are used and its bytes are not committed.
Record details
- Record id
maternal:sflt1-plgf-ratio- Content hash
43e5240d4c37a76469df35f6528f8f9e62ba15dccc542046c68f511d19a378d0