Closing a patent ductus arteriosus by a procedure means either surgical ligation or a device placed through a catheter. A 2023 overview of Cochrane reviews says surgery is mostly kept for babies whose ductus stays symptomatic after medicines have failed, and that survivors of ligation were found to be at higher risk of neurodevelopmental impairment, though the studies may be biased. A 2021 expert consensus on a catheter device used in the smallest premature babies reports a high implant success rate and few serious complications, written by a panel that included the device maker's staff and consultants. This page gives no advice on technique.
Also called Transcatheter PDA closure · Surgical PDA ligation · Invasive PDA closure
- Intervention
- In this atlas
Overview
Technical summary
Procedure; no MeSH descriptor is written. Sources read: the 2023 Cochrane overview (PMC10091483, text reused from an earlier record, CC BY 4.0; background and results on surgical ligation) and a 2021 consensus (PMC8292293, CC BY 4.0). The consensus panel included interventional cardiologists and representatives of Abbott, the maker of the Amplatzer Piccolo Occluder; its conflict-of-interest statement lists an Abbott employee and several Abbott proctors or consultants. It is a consensus on complications, not a trial. All technique, sizing and management detail is left out. No product record exists for the device, so none is linked. Existing atlas records on the ductus and its medicines are linked and not repeated.
About this intervention
- Type
- Procedure
- Mechanism
- Not reported
Claims and evidence
Context Extremely low birth weight infants (2021 consensus on a catheter device)
- Recipient
- Newborn
- Population
- Extremely low birth weight infants, as a panel of specialists describes them, with figures from a US premarket trial of a catheter device in patients weighing 700 g or more.
- Care setting
- Catheterisation laboratory and neonatal unit
- Geography
- United States for the premarket trial; panel members not located in the abstract
- Life stage
- Extremely low birth weight infants; the abstract gives no age band
- Gestational age
- Not reported
- Postnatal age
- Not reported
- Follow-up
- Not applicable (literature review)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Extremely low birth weight infants, as a panel of specialists describes them, with figures from a US premarket trial of a catheter device in patients weighing 700 g or more
- Excluded
- None stated
A 2021 consensus article says transcatheter closure in premature infants is a feasible, safe and effective alternative to surgical ligation with an implant success rate of 97%, and that major procedural complications in extremely low birth weight infants are relatively infrequent (under 3%) but may be fatal if not managed well. It describes the Amplatzer Piccolo Occluder as the first device approved for infants as small as 700 grams.
Applies to Newborn Extremely low birth weight infants (2021 consensus on a catheter device)
- Certainty method
- Not assessed
- Limitations
- The panel was convened to analyse complications and included device-manufacturer representatives; the conflict-of-interest statement lists an Abbott employee and Abbott proctors or consultants. The figures come from the consensus and the premarket trial it cites (implant success 95.5% overall), not from a randomised comparison with surgery. The consensus gives technique, sizing and management detail that is not repeated.
- Last checked
- 2026-11-19
- Next evidence check due
- Not scheduled
Sources and citations (4)
-
- Locator
- Abstract, paragraph 1, sentence 1
- How it applies
- Passage in the source that backs the claim.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
fed9cb857e0930a56bc157069b70360e43bd8bc65e558f9ae508a1f6e59c190f- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
-
- Locator
- Abstract, paragraph 1, sentence 2
- How it applies
- Passage in the source that backs the claim.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
fed9cb857e0930a56bc157069b70360e43bd8bc65e558f9ae508a1f6e59c190f- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
-
- Locator
- Introduction, paragraph 2, sentence 1
- How it applies
- Passage in the source that backs the claim.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
fed9cb857e0930a56bc157069b70360e43bd8bc65e558f9ae508a1f6e59c190f- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
-
- Locator
- Introduction, paragraph 2, sentence 2
- How it applies
- Passage in the source that backs the claim.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
fed9cb857e0930a56bc157069b70360e43bd8bc65e558f9ae508a1f6e59c190f- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; read from the full permissions element of the article XML, which has no non-commercial or no-derivatives wording). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
Context Preterm or low-birth-weight infants in Cochrane reviews (2023 overview)
- Recipient
- Newborn
- Population
- Preterm or low-birth-weight infants with patent ductus arteriosus in the Cochrane reviews the overview summarises, including one trial of 154 infants comparing ligation with indomethacin.
- Care setting
- Neonatal units (not stated in the abstract)
- Geography
- Not stated in the abstract
- Life stage
- Neonatal period; the abstract gives no age band
- Gestational age
- Not reported
- Postnatal age
- Not reported
- Follow-up
- Not applicable (literature review)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Preterm or low-birth-weight infants with patent ductus arteriosus in the Cochrane reviews the overview summarises, including one trial of 154 infants comparing ligation with indomethacin
- Excluded
- None stated
The 2023 Cochrane overview says surgical ligation is mainly kept for infants with a persistent symptomatic ductus after medical treatment has failed, and is no longer a preferred way to prevent a ductus. It reports that ligation is associated with lower mortality but that survivors were found to be at higher risk of neurodevelopmental impairment, possibly because of survival bias and confounding by indication. In one trial, ligation reduced failure of closure compared with indomethacin.
Applies to Newborn Preterm or low-birth-weight infants in Cochrane reviews (2023 overview)
- Certainty method
- Not assessed
- Limitations
- Statements in the overview's background describe other studies; the overview did not test them. The single trial result is from one review. Certainty is not assessed here.
- Last checked
- 2026-11-19
- Next evidence check due
- Not scheduled
Sources and citations (4)
-
- Locator
- Background, Description of the interventions, paragraph 5, sentence 1
- How it applies
- Passage in the source that backs the claim.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
d7d48a79fb081b8a4621bb2eff4de52d98df3a208b7a2990b57d3ed9da9a40ca- Reuse basis
- PMC Open Access article under https://creativecommons.org/licenses/by/4.0/ (the licence element of the fetched XML, content-type ccbylicense). The XML is committed unaltered in the atlas repository.
-
- Locator
- Background, Description of the interventions, paragraph 5, sentence 2
- How it applies
- Passage in the source that backs the claim.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
d7d48a79fb081b8a4621bb2eff4de52d98df3a208b7a2990b57d3ed9da9a40ca- Reuse basis
- PMC Open Access article under https://creativecommons.org/licenses/by/4.0/ (the licence element of the fetched XML, content-type ccbylicense). The XML is committed unaltered in the atlas repository.
-
- Locator
- Background, How the intervention might work, paragraph 1, sentence 3
- How it applies
- Passage in the source that backs the claim.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
d7d48a79fb081b8a4621bb2eff4de52d98df3a208b7a2990b57d3ed9da9a40ca- Reuse basis
- PMC Open Access article under https://creativecommons.org/licenses/by/4.0/ (the licence element of the fetched XML, content-type ccbylicense). The XML is committed unaltered in the atlas repository.
-
- Locator
- Results, Effect of interventions, Interventions (pharmacological or surgical) for management of symptomatic (haemodynamically significant) PDA in preterm infants, Failure of PDA closure after completion of allocated treatment, Surgical ligation, paragraph 1, sentence 1
- How it applies
- Passage in the source that backs the claim.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
d7d48a79fb081b8a4621bb2eff4de52d98df3a208b7a2990b57d3ed9da9a40ca- Reuse basis
- PMC Open Access article under https://creativecommons.org/licenses/by/4.0/ (the licence element of the fetched XML, content-type ccbylicense). The XML is committed unaltered in the atlas repository.
Clinical links
Each link reports what one cited claim says about one population. "Evaluated for" means studied, not shown to work. These links do not show that anything is effective or right for you.
-
Claim, not a settled fact Surgical ligation and transcatheter closure in preterm infants: Cochrane overview and device consensus: Patent ductus arteriosus
Applies to Newborn Extremely low birth weight infants (2021 consensus on a catheter device)
A 2021 consensus article says transcatheter closure in premature infants is a feasible, safe and effective alternative to surgical ligation with an implant success rate of 97%, and that major procedural complications in extremely low birth weight infants are relatively infrequent (under 3%) but may be fatal if not managed well. It describes the Amplatzer Piccolo Occluder as the first device approved for infants as small as 700 grams.Limitations. The panel was convened to analyse complications and included device-manufacturer representatives; the conflict-of-interest statement lists an Abbott employee and Abbott proctors or consultants. The figures come from the consensus and the premarket trial it cites (implant success 95.5% overall), not from a randomised comparison with surgery. The consensus gives technique, sizing and management detail that is not repeated.