Invasive mechanical ventilation for newborns

Invasive mechanical ventilation is breathing support for a baby through a tube in the windpipe, used in a neonatal intensive care unit. A 2025 review says that breathing support without a tube is the first choice for babies with breathing trouble, and that nearly 40% of very low birth weight babies and 80% of extremely premature babies need a tube and machine at some point. The same review prefers modes in which the machine aims for a set breath size (volume-targeted ventilation), and keeps the high-frequency mode for rescue. A 2020 review of the smallest babies says there is no clear agreement on the best primary mode. This page gives no advice on settings or on when to start or stop.

Also called Neonatal mechanical ventilation · Volume-targeted ventilation · Ventilator support for newborns

  • Intervention
  • In this atlas

Overview

Technical summary

Procedure (MeSH D012121 Respiration, Artificial, broad: the descriptor covers artificial respiration in people of any age). Sources read: the MeSH concept scope note, a 2025 evidence-based review of invasive ventilation in neonates (PMC12310796), a 2020 review of volume-targeted and high-frequency ventilation as primary modes for ELBW babies (PMC7025474) and a 2022 review of weaning and extubation (PMC9670452), all CC BY 4.0, with abstracts and selected paragraphs read. Not read: any guideline, any trial, or the tables of recommendations by condition in the 2025 review. The 2025 review states recommendations; this page reports them as the authors statements, not as the atlas advice. The 2025 and 2020 reviews differ in strength: the first prefers volume-targeted ventilation, the second says no mode has been shown to be preferable as the primary mode in ELBW babies. Recipients are newborns on every claim.

About this intervention

Type
Procedure
Mechanism
Not reported

Classification codes

  • MeSH id.nlm.nih.gov linked data, retrieved 2026-11-18; descriptor lastUpdated 2015-07-06; no yearly MeSH release stated D012121 Respiration, Artificial

Claims and evidence

Context A vocabulary definition (MeSH), not a study population

Recipient
No clinical recipient
Population
Not applicable: a controlled-vocabulary definition from the National Library of Medicine, with no population.
Care setting
Not applicable (vocabulary)
Geography
Not applicable (vocabulary)
Life stage
Not applicable (vocabulary)
Follow-up
Not applicable (vocabulary)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
  • Not applicable (vocabulary)
Excluded
None stated
  • Description Evidence stage not applicable Certainty not assessed

    The National Library of Medicine vocabulary MeSH defines artificial respiration as any method of artificial breathing that uses mechanical or non-mechanical means to force air into and out of the lungs, used when a person has stopped breathing or has respiratory insufficiency.

    Applies to No clinical recipient A vocabulary definition (MeSH), not a study population

    Certainty method
    Not assessed
    Limitations
    A vocabulary definition for people of any age, not a statement about newborns and not a recommendation.
    Last checked
    2026-11-18
    Next evidence check due
    Not scheduled
    Sources and citations (1)
    1. Supports MeSH concept M0018880 (Respiration, Artificial)

      Dataset · U.S. National Library of Medicine · Edition MeSH linked-data concept record as fetched on 2026-10-30. It holds the concept label and its scope note, and states no date.

      Locator
      scopeNote.@value
      How it applies
      MeSH scope note (NLM, attribution given). A definition, not a clinical finding.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      2376ce525e0ba0f6e2ded1f008d3d1633b8a72a326d2fcf0f85f11dfe1d35f14
      Reuse basis
      The NLM web policies page (sha256 c8b7026b5c3fcfd1b0cb88755077f6a99a5f2159eecd42b0e7d1a5ad9b30ec55) says works produced by the U.S. government are not subject to copyright protection in the United States and asks users to acknowledge NLM as the source. Source: National Library of Medicine. The NLM terms and conditions page (sha256 f1fb494447a54d2190e496410163c8e1fc138a601d83d8c124f267f7103026b3) asks redistributors to maintain the most current data or to make known clearly that their copy may not reflect the most current data available from NLM. This copy was fetched on 2026-10-30 and may not reflect the most current data. The raw bytes are committed in the atlas repository.

Context Extremely low birth weight (ELBW) infants who need ventilation, as a 2020 review describes them

Recipient
Newborn
Population
Extremely low birth weight (ELBW) newborns with respiratory failure who are on invasive ventilation, as the authors of a 2020 review describe them. The review notes that studies on ELBW babies specifically are few.
Geography
Not stated in the abstract
Life stage
Extremely low birth weight newborns
Gestational age
Not reported
Postnatal age
Not reported
Follow-up
Not applicable (literature review)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
  • Extremely low birth weight newborns on invasive ventilation
Excluded
None stated
  • Effect Evidence synthesis Certainty not assessed

    A 2020 review of invasive ventilation in extremely low birth weight babies says there is no clear agreement on which mode is best as the primary mode, that volume-targeted and high-frequency jet ventilation show promise in some studies, and that those studies were not powered to show lower death or illness. It says that incidence of chronic lung disease has not fallen despite advances, and calls for larger studies in this group.

    Applies to Newborn Extremely low birth weight (ELBW) infants who need ventilation, as a 2020 review describes them

    Certainty method
    Not assessed
    Limitations
    A 2020 narrative review that weighed the evidence by mode; it predates the 2025 review and is more cautious, partly because few studies include only the smallest babies. The atlas did not read the studies behind it.
    Last checked
    2026-11-18
    Next evidence check due
    Not scheduled
    Sources and citations (1)
    1. Supports Volume Targeted Ventilation and High Frequency Ventilation as the Primary Modes of Respiratory Support for ELBW Babies: What Does the Evidence Say?

      Publication · Frontiers in Pediatrics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2020). Used: abstract and selected paragraphs. · PMCID: PMC7025474

      Locator
      Conclusion, paragraph 1; Abstract, paragraph 1
      How it applies
      Full-text open-access review (CC BY 4.0), read in the PMC XML.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3a84f0e55f2379e33e61a6f73cb4091ed4999e0c2086b08eefa06e242627587b
      Reuse basis
      PMC Open Access subset article under http://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Context Newborns being weaned from invasive mechanical ventilation, as a 2022 review describes them

Recipient
Newborn
Population
Newborns, mostly preterm, who are being weaned from invasive mechanical ventilation, as the authors of a 2022 review of weaning and extubation describe them.
Geography
Not stated in the abstract
Life stage
Newborn period
Gestational age
Not reported
Postnatal age
Not reported
Follow-up
Not applicable (literature review)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
  • Newborns on invasive mechanical ventilation who may be weaned
Excluded
None stated
  • Recommendation Evidence synthesis Certainty not assessed

    A 2022 review says that neonatologists are advised to consider weaning newborns from invasive ventilation as soon as possible, and the 2025 review says there is no single tool for judging whether a baby is ready for extubation.

    Applies to Newborn Newborns being weaned from invasive mechanical ventilation, as a 2022 review describes them

    Certainty method
    Not assessed
    Limitations
    Statements in reviews, not a guideline. The 2022 review includes the weaning protocol of one unit, which this page does not state, and neither review gives criteria that this page repeats.
    Last checked
    2026-11-18
    Next evidence check due
    Not scheduled
    Sources and citations (2)
    1. Supports Weaning and extubation from neonatal mechanical ventilation: an evidenced-based review

      Publication · BMC Pulmonary Medicine · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2022). Used: abstract and selected paragraphs. · PMCID: PMC9670452

      Locator
      Abstract, paragraph 1
      How it applies
      Full-text open-access review (CC BY 4.0), read in the PMC XML.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      d51461e11e6b62baea88d9f0f470664f385697d76f398038a37ae69298890393
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
    2. Supports Invasive Ventilation Strategies in Neonates

      Publication · Indian Pediatrics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2025). Used: abstract and selected paragraphs. · PMCID: PMC12310796

      Locator
      Extubation Readiness, paragraph 1
      How it applies
      Full-text open-access review (CC BY 4.0), read in the PMC XML.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      ebcc0173a783fa6e76356c0daa9c24b778eac8c795a50c2e3eab1192edc95ee8
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Context Newborns in a neonatal intensive care unit who need invasive mechanical ventilation, as a 2025 review describes them

Recipient
Newborn
Population
Newborns whose breathing is supported through an endotracheal or tracheostomy tube in a neonatal intensive care unit, as the authors of a 2025 evidence-based review describe them. The review covers preterm and term babies and several lung and heart conditions.
Care setting
Neonatal intensive care unit
Geography
Not stated in the abstract (the review searched international databases)
Life stage
Newborn period, preterm and term
Gestational age
Not reported
Postnatal age
Not reported
Follow-up
Not applicable (literature review)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
Excluded
None stated
  • Recommendation Evidence synthesis Certainty not assessed

    The 2025 review recommends synchronized, patient-triggered modes with volume-targeted ventilation for newborns who need invasive ventilation, says that evidence suggests that adding volume targeting to pressure-limited ventilation reduces bronchopulmonary dysplasia, intraventricular haemorrhage, air leaks and ventilation time, and says that current evidence does not support routine use of high-frequency ventilation as the primary support, which it would keep as rescue support for air leaks and severe lung disease.

    Applies to Newborn Newborns in a neonatal intensive care unit who need invasive mechanical ventilation, as a 2025 review describes them

    Certainty method
    Not assessed
    Limitations
    A review of the past five years of literature that states its own recommendations; it is not a guideline and the atlas did not read the trials behind it. It says that volume-targeted ventilation is not used everywhere because some universal ventilators may lack the accuracy needed for very small breaths. The 2020 review below is less sure about the primary mode in the smallest babies.
    Last checked
    2026-11-18
    Next evidence check due
    Not scheduled
    Sources and citations (1)
    1. Supports Invasive Ventilation Strategies in Neonates

      Publication · Indian Pediatrics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2025). Used: abstract and selected paragraphs. · PMCID: PMC12310796

      Locator
      Conclusions, paragraph 1; Volume-Targeted Ventilation, paragraph 1
      How it applies
      Full-text open-access review (CC BY 4.0), read in the PMC XML.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      ebcc0173a783fa6e76356c0daa9c24b778eac8c795a50c2e3eab1192edc95ee8
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
  • Burden Evidence synthesis Certainty not assessed

    The 2025 review says that respiratory distress is the most common reason for neonatal intensive care admission and mechanical ventilation, and that nearly 40% of very low birth weight babies and 80% of extremely premature babies (under 28 weeks of gestation) need invasive mechanical ventilation at some point.

    Applies to Newborn Newborns in a neonatal intensive care unit who need invasive mechanical ventilation, as a 2025 review describes them

    Certainty method
    Not assessed
    Limitations
    Figures from the introduction of the review, which cites other studies the atlas did not read. No time period, country or year is given for them.
    Last checked
    2026-11-18
    Next evidence check due
    Not scheduled
    Sources and citations (1)
    1. Supports Invasive Ventilation Strategies in Neonates

      Publication · Indian Pediatrics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2025). Used: abstract and selected paragraphs. · PMCID: PMC12310796

      Locator
      Introduction, paragraph 1
      How it applies
      Full-text open-access review (CC BY 4.0), read in the PMC XML.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      ebcc0173a783fa6e76356c0daa9c24b778eac8c795a50c2e3eab1192edc95ee8
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
  • Description Evidence synthesis Certainty not assessed

    A 2025 review defines invasive mechanical ventilation in neonates as the delivery of positive pressure to the lungs through an endotracheal or tracheostomy tube, with the goal of correcting lung function and restoring gas exchange. The review says that breathing support without a tube (noninvasive ventilation) is the first-line approach for newborn respiratory distress, and that invasive ventilation is needed when it fails, is less effective or is contraindicated.

    Applies to Newborn Newborns in a neonatal intensive care unit who need invasive mechanical ventilation, as a 2025 review describes them

    Certainty method
    Not assessed
    Limitations
    The authors statements in a review, not a guideline. The review says the choice of mode and timing is a matter for an experienced clinician. This page gives no criteria for starting ventilation.
    Last checked
    2026-11-18
    Next evidence check due
    Not scheduled
    Sources and citations (1)
    1. Supports Invasive Ventilation Strategies in Neonates

      Publication · Indian Pediatrics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2025). Used: abstract and selected paragraphs. · PMCID: PMC12310796

      Locator
      Introduction, paragraph 2; Conclusions, paragraph 1
      How it applies
      Full-text open-access review (CC BY 4.0), read in the PMC XML.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      ebcc0173a783fa6e76356c0daa9c24b778eac8c795a50c2e3eab1192edc95ee8
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Context Newborns in randomised trials of volume-targeted against pressure-limited ventilation, as a 2020 review reports a 2017 Cochrane analysis

Recipient
Newborn
Population
Newborns in the 16 parallel and 4 cross-over studies (data from 977 infants) of a 2017 Cochrane meta-analysis that compared volume-targeted with pressure-limited ventilation, as the authors of a 2020 review report it. The 2020 review notes there is very little data on ELBW babies specifically.
Care setting
Neonatal intensive care units in clinical studies
Geography
Not stated in the review text read
Life stage
Newborn period, mainly preterm infants
Gestational age
Not reported
Postnatal age
Not reported
Follow-up
Not applicable (the review reports a meta-analysis it did not run)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
Excluded
None stated
  • Effect Evidence synthesis Certainty not assessed

    The 2020 review reports a 2017 Cochrane meta-analysis of 16 parallel and 4 cross-over studies (977 infants) in which volume-targeted ventilation, against pressure-limited ventilation, was found to significantly decrease death or bronchopulmonary dysplasia, time on ventilation, air leaks, hypocarbia and severe intraventricular haemorrhage.

    Applies to Newborn Newborns in randomised trials of volume-targeted against pressure-limited ventilation, as a 2020 review reports a 2017 Cochrane analysis

    Certainty method
    Not assessed
    Limitations
    Reported second-hand: the atlas did not read the Cochrane review. The 2020 authors note that there is very little data on ELBW babies specifically.
    Last checked
    2026-11-18
    Next evidence check due
    Not scheduled
    Sources and citations (1)
    1. Supports Volume Targeted Ventilation and High Frequency Ventilation as the Primary Modes of Respiratory Support for ELBW Babies: What Does the Evidence Say?

      Publication · Frontiers in Pediatrics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2020). Used: abstract and selected paragraphs. · PMCID: PMC7025474

      Locator
      Volume Targeted (VTV) vs. Pressure Limited Ventilation (PLV) in ELBW infants, paragraph 1
      How it applies
      Full-text open-access review (CC BY 4.0), read in the PMC XML.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      3a84f0e55f2379e33e61a6f73cb4091ed4999e0c2086b08eefa06e242627587b
      Reuse basis
      PMC Open Access subset article under http://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Context Preterm infants on invasive mechanical ventilation, as a 2025 review describes their risks

Recipient
Newborn
Population
Preterm infants who receive invasive mechanical ventilation, as the authors of a 2025 review describe them. The review gives no single gestational age or weight cut-off for the statement on risks.
Geography
Not stated
Life stage
Preterm newborn period
Gestational age
Not reported
Postnatal age
Not reported
Follow-up
Not applicable (literature review)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
Included
  • Preterm infants on invasive mechanical ventilation
Excluded
None stated
  • Safety Evidence synthesis Certainty not assessed

    The 2025 review says that invasive ventilation is a major cause of ventilator-induced lung injury, and that preterm infants on invasive ventilation are at increased risk of sepsis, ventilator-associated pneumonia, air leaks, bronchopulmonary dysplasia and adverse neurodevelopmental outcomes.

    Applies to Newborn Preterm infants on invasive mechanical ventilation, as a 2025 review describes their risks

    Certainty method
    Not assessed
    Limitations
    Authors statements in a review, not measured risks; no rates are given and the review gives no gestational age cut-off for them.
    Last checked
    2026-11-18
    Next evidence check due
    Not scheduled
    Sources and citations (1)
    1. Supports Invasive Ventilation Strategies in Neonates

      Publication · Indian Pediatrics · Edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2025). Used: abstract and selected paragraphs. · PMCID: PMC12310796

      Locator
      Introduction, paragraph 2; Extubation Readiness, paragraph 2
      How it applies
      Full-text open-access review (CC BY 4.0), read in the PMC XML.
      Retrieved
      Source effective date
      Not reported
      Source state
      Current
      Version fingerprint
      ebcc0173a783fa6e76356c0daa9c24b778eac8c795a50c2e3eab1192edc95ee8
      Reuse basis
      PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.

Record details

Record id
maternal:neonatal-mechanical-ventilation
Content hash
02b130eb75e8b7cd6907fa0ed8be145106ad31cb31071b3cd2f4b89fcfe0025f