Transient tachypnea of the newborn
Transient tachypnea of the newborn (TTN) is fast breathing in a newborn; MeSH attributes it to delayed clearance of fetal lung fluid. A 2026 review says it is a self-limiting condition whose symptoms typically settle within 24 to 48 hours, and a major cause of newborn breathing trouble, accounting for about a third to a half of cases. Another 2026 review says about 10% of babies born at 33 to 34 weeks have it, 5% at 35 to 36 weeks and under 1% at 37 weeks or more. Two meta-analyses of lung ultrasound for diagnosing it disagree on sensitivity: 0.67 in a 2021 analysis of seven studies and 0.93 in a 2026 analysis of ten, both with high heterogeneity. A 2026 meta-analysis found that nebulized salbutamol may shorten breathing support, though the certainty was low to very low. This page gives no advice on treatment.
Also called TTN · Transient tachypnoea of the newborn · Wet lung
- Condition
- In this atlas
Overview
Technical summary
Condition. MeSH D059245 (exact; the concept scope note links it to delayed fetal lung fluid clearance, often after caesarean birth). Sources read: the MeSH scope note and three CC BY 4.0 reviews, with abstracts and selected paragraphs read: a 2021 meta-analysis of lung ultrasound (PMC8006999, 7 studies), a 2026 meta-analysis of lung ultrasound (PMC13342246, 10 studies) and a 2026 meta-analysis of nebulized salbutamol (PMC13630241, 17 randomised trials). The two ultrasound meta-analyses give different pooled sensitivity (0.67 and 0.93) and both report high heterogeneity; the page shows both. Not read: any guideline, any trial, any drug label. The page states no dose. Recipients are newborns on every claim.
Burden
A 2026 meta-analysis says that transient tachypnea of the newborn causes fast breathing (over 60 breaths a minute), nasal flaring, grunting and chest retractions soon after birth, and that about 10% of infants born at 33 to 34 weeks are affected, about 5% at 35 to 36 weeks and under 1% at 37 weeks or later.
Applies to Newborn Near-term and term newborns with transient tachypnea of the newborn, as reviews describe them
Population, setting and follow-up
- Newborns with transient tachypnea of the newborn (a self-limiting breathing problem from delayed clearance of lung fluid), mostly near-term and term babies, as the authors of reviews describe them.
- Newborn and neonatal care
- Not stated in the abstracts
- First days after birth
- Gestational age Not reported
- Postnatal age Not reported
- Certainty method
- Not assessed
- Limitations
- Figures quoted from the introduction of a review that cites other studies; no country or year is given. The atlas did not read the studies.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
- Locator
- Introduction, paragraph 1
- How it applies
- Full-text open-access review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
d9acdbf67208e79969d96585d1f4b8fdcca114832acfe1d6bbfaf8f5646bff1f- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
Claims and evidence
Context A vocabulary definition (MeSH), not a study population
- Recipient
- No clinical recipient
- Population
- Not applicable: a controlled-vocabulary definition from the National Library of Medicine, with no population.
- Care setting
- Not applicable (vocabulary)
- Geography
- Not applicable (vocabulary)
- Life stage
- Not applicable (vocabulary)
- Follow-up
- Not applicable (vocabulary)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Not applicable (vocabulary)
- Excluded
- None stated
The National Library of Medicine vocabulary MeSH defines transient tachypnea of the newborn as an abnormal increase in the newborn's respiratory rate that is self-limiting and attributed to delayed clearance of fetal lung fluid, often after caesarean section delivery.
Applies to No clinical recipient A vocabulary definition (MeSH), not a study population
- Certainty method
- Not assessed
- Limitations
- A vocabulary definition, not a clinical finding or a diagnostic criterion.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
Supports MeSH concept M0549003 (preferred concept of descriptor D059245, Transient Tachypnea of the Newborn)
- Locator
- scopeNote.@value
- How it applies
- MeSH scope note (NLM, attribution given). A definition, not a clinical finding.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
ce1bb2cf1849eced205dd6241a9fffeda72dd680fbc7d89b4f6390f073e6e995- Reuse basis
- The NLM web policies page (https://www.nlm.nih.gov/web_policies.html), re-read 2026-11-18 (sha256 c8b7026b5c3fcfd1b0cb88755077f6a99a5f2159eecd42b0e7d1a5ad9b30ec55, hash only), says works produced by the U.S. government are not subject to copyright protection in the United States and asks users to acknowledge NLM as the source. Source: National Library of Medicine. The raw bytes are committed in the atlas repository.
Context Infants with transient tachypnea of the newborn in randomised trials of nebulized salbutamol, in a 2026 meta-analysis
- Recipient
- Newborn
- Population
- Infants with transient tachypnea of the newborn in the 17 randomised trials (1,317 infants) pooled by the authors of a 2026 systematic review and meta-analysis. The review notes that the trials differed in the severity of the infants.
- Care setting
- Neonatal units in randomised trials
- Geography
- Not stated in the abstract
- Life stage
- Newborn period, mostly near-term and term infants
- Gestational age
- Not reported
- Postnatal age
- Not reported
- Follow-up
- Not applicable (meta-analysis of trials)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Infants with transient tachypnea of the newborn
- Excluded
- None stated
A 2026 review with a meta-analysis of 17 randomised trials (1,317 infants) found that nebulized salbutamol shortened respiratory support, CPAP, oxygen need and hospital stay in infants with transient tachypnea of the newborn, but not the duration of fast breathing. The authors rate the certainty of the evidence as low to very low, say the benefit may be limited to more severe cases, and say that other treatments studied have not been adopted as standard practice.
Applies to Newborn Infants with transient tachypnea of the newborn in randomised trials of nebulized salbutamol, in a 2026 meta-analysis
- Certainty method
- Not assessed
- Limitations
- Low to very low certainty, as the authors say. The atlas read no drug label and no trial for this use, and states no dose or product. Nebulized salbutamol is a drug; whether it is licensed for this use was not checked.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
- Locator
- Abstract, paragraph 1; Conclusions, paragraph 1; Introduction, paragraph 5
- How it applies
- Full-text open-access review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
d9acdbf67208e79969d96585d1f4b8fdcca114832acfe1d6bbfaf8f5646bff1f- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
Context Near-term and term newborns with transient tachypnea of the newborn, as reviews describe them
- Recipient
- Newborn
- Population
- Newborns with transient tachypnea of the newborn (a self-limiting breathing problem from delayed clearance of lung fluid), mostly near-term and term babies, as the authors of reviews describe them.
- Care setting
- Newborn and neonatal care
- Geography
- Not stated in the abstracts
- Life stage
- First days after birth
- Gestational age
- Not reported
- Postnatal age
- Not reported
- Follow-up
- Not applicable (literature reviews)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Newborns with transient tachypnea of the newborn
- Excluded
- None stated
A 2026 meta-analysis describes transient tachypnea of the newborn as a self-limiting respiratory condition caused by delayed clearance of fetal lung fluid, which causes about 33% to 50% of newborn respiratory distress. It says the symptoms are generally transient and typically settle within 24 to 48 hours, and that severe cases may need high-concentration oxygen or even mechanical ventilation. A 2021 meta-analysis adds that the clinical signs overlap with many other conditions.
Applies to Newborn Near-term and term newborns with transient tachypnea of the newborn, as reviews describe them
- Certainty method
- Not assessed
- Limitations
- Statements in the introductions of reviews, which cite studies the atlas did not read. The 33% to 50% share is the authors citation and no country or year is given.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (2)
-
Supports Diagnostic accuracy of lung ultrasound for transient tachypnea of the newborn: a meta-analysis
- Locator
- Introduction, paragraph 1
- How it applies
- Full-text open-access review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
b1c34137e23630348afb42729088ee1f2300aebf18d0a175c36af867fdb22db4- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
-
Supports Diagnostic performance of lung ultrasound for transient tachypnea of the newborn: A meta-analysis
- Locator
- Introduction, paragraph 1
- How it applies
- Full-text open-access review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
0e402e9ab95a0723cb5c24b14644db8779f65df99b4ccd6977657e365b3669e3- Reuse basis
- PMC Open Access subset article under http://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
Context Newborns assessed by lung ultrasound for transient tachypnea of the newborn, in a 2021 meta-analysis
- Recipient
- Newborn
- Population
- Newborns in the seven studies (1514 participants) pooled by the authors of a 2021 meta-analysis of lung ultrasound for diagnosing transient tachypnea of the newborn.
- Care setting
- Neonatal units in diagnostic studies
- Geography
- Not stated in the abstract
- Life stage
- Newborn period
- Gestational age
- Not reported
- Postnatal age
- Not reported
- Follow-up
- Not applicable (diagnostic accuracy studies)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Newborns with suspected transient tachypnea of the newborn who had a lung ultrasound
- Excluded
- None stated
A 2021 meta-analysis of seven studies with 1514 participants found that lung ultrasound had pooled sensitivity of 0.67 and specificity of 0.97 for diagnosing transient tachypnea of the newborn. The authors say that heterogeneity was high, that only seven studies with small samples were included, and that more studies are needed.
Applies to Newborn Newborns assessed by lung ultrasound for transient tachypnea of the newborn, in a 2021 meta-analysis
- Certainty method
- Not assessed
- Limitations
- Few and small studies with high heterogeneity, as the authors say. The 2026 meta-analysis below reports a much higher sensitivity; the two are not reconciled here.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
Supports Diagnostic performance of lung ultrasound for transient tachypnea of the newborn: A meta-analysis
- Locator
- Abstract, paragraph 1; Results / Diagnostic accuracy of DLP for TTN, paragraph 1; Conclusions, paragraph 1
- How it applies
- Full-text open-access review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
0e402e9ab95a0723cb5c24b14644db8779f65df99b4ccd6977657e365b3669e3- Reuse basis
- PMC Open Access subset article under http://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
Context Newborns assessed by lung ultrasound for transient tachypnea of the newborn, in a 2026 meta-analysis
- Recipient
- Newborn
- Population
- Newborns in the ten studies (1,747 newborns) pooled by the authors of a 2026 meta-analysis of the accuracy of lung ultrasound for diagnosing transient tachypnea of the newborn. Three of the ten studies were case-control studies.
- Care setting
- Neonatal units in diagnostic studies
- Geography
- Not stated in the abstract
- Life stage
- Newborn period
- Gestational age
- Not reported
- Postnatal age
- Not reported
- Follow-up
- Not applicable (diagnostic accuracy studies)
Eligibility: 1 inclusion criterion; exclusion criteria not stated
- Included
- Newborns with suspected transient tachypnea of the newborn who had a lung ultrasound
- Excluded
- None stated
A 2026 meta-analysis of ten studies with 1,747 newborns found a pooled sensitivity of 0.93 and specificity of 0.99 for lung ultrasound in diagnosing transient tachypnea of the newborn. The authors conclude that it is promising but that accuracy varies considerably with study design and diagnostic criteria, and they note that three of the ten studies were case-control studies, which may overestimate accuracy.
Applies to Newborn Newborns assessed by lung ultrasound for transient tachypnea of the newborn, in a 2026 meta-analysis
- Certainty method
- Not assessed
- Limitations
- The authors report substantial heterogeneity and a limited sample, and say that case-control designs could overestimate sensitivity and specificity. It is a diagnostic accuracy finding, not a statement about outcomes or about replacing the chest X-ray.
- Last checked
- 2026-11-18
- Next evidence check due
- Not scheduled
Sources and citations (1)
-
Supports Diagnostic accuracy of lung ultrasound for transient tachypnea of the newborn: a meta-analysis
- Locator
- Abstract / Results, paragraph 1; Abstract / Conclusion, paragraph 1; Discussion, paragraph 4
- How it applies
- Full-text open-access review (CC BY 4.0), read in the PMC XML.
- Retrieved
- Source effective date
- Not reported
- Source state
- Current
- Version fingerprint
b1c34137e23630348afb42729088ee1f2300aebf18d0a175c36af867fdb22db4- Reuse basis
- PMC Open Access subset article under https://creativecommons.org/licenses/by/4.0/ (CC BY 4.0; the article's own permissions element). The raw XML from NCBI E-utilities is committed unaltered in the atlas repository, which the licence allows with attribution. Short quotations under 25 words.
Registry records
Assembled by a program from ClinicalTrials.gov. No person wrote or checked these pages, and they are counted apart from the pages that people wrote. Lists of trials come from the registry's own coding and may miss trials.
Registry trials 6
Record details
- Record id
maternal:transient-tachypnea-of-the-newborn- Content hash
bb0804eaf690f59bdb9d9724eb4613c522a3ad0aad61a49cac2923b4e3365bdc