# Transient tachypnea of the newborn

Condition · id `maternal:transient-tachypnea-of-the-newborn` · Maternal & Newborn Atlas · release `8f5d5a5ed7ba4f08` (public)

> General information from published sources, not medical advice, and not reviewed by clinicians. Check the cited source before relying on anything here. Sponsors do not influence what this atlas says.

The atlas's own text and curation may be reused under Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0, https://creativecommons.org/licenses/by-nc/4.0/): credit the atlas, and do not use it commercially without a licence from the owner. See the atlas About page. Text quoted from a source stays under that source's own terms, given as the source's reuse\_basis. The atlas's reuse terms do not cover it. The downloads list each quotation with its source in third\_party\_quotations.

Also called: TTN; Transient tachypnoea of the newborn; Wet lung

Browse, life stage: Newborn  
Browse, care area: Preterm and sick newborns  

## In plain language

Transient tachypnea of the newborn (TTN) is fast breathing in a newborn; MeSH attributes it to delayed clearance of fetal lung fluid. A 2026 review says it is a self-limiting condition whose symptoms typically settle within 24 to 48 hours, and a major cause of newborn breathing trouble, accounting for about a third to a half of cases. Another 2026 review says about 10% of babies born at 33 to 34 weeks have it, 5% at 35 to 36 weeks and under 1% at 37 weeks or more. Two meta-analyses of lung ultrasound for diagnosing it disagree on sensitivity: 0.67 in a 2021 analysis of seven studies and 0.93 in a 2026 analysis of ten, both with high heterogeneity. A 2026 meta-analysis found that nebulized salbutamol may shorten breathing support, though the certainty was low to very low. This page gives no advice on treatment.

## Technical summary

Condition. MeSH D059245 (exact; the concept scope note links it to delayed fetal lung fluid clearance, often after caesarean birth). Sources read: the MeSH scope note and three CC BY 4.0 reviews, with abstracts and selected paragraphs read: a 2021 meta-analysis of lung ultrasound (PMC8006999, 7 studies), a 2026 meta-analysis of lung ultrasound (PMC13342246, 10 studies) and a 2026 meta-analysis of nebulized salbutamol (PMC13630241, 17 randomised trials). The two ultrasound meta-analyses give different pooled sensitivity (0.67 and 0.93) and both report high heterogeneity; the page shows both. Not read: any guideline, any trial, any drug label. The page states no dose. Recipients are newborns on every claim.

## Claims, with the population each applies to

## Context: A vocabulary definition (MeSH), not a study population

Recipient: No clinical recipient; Population: Not applicable: a controlled-vocabulary definition from the National Library of Medicine, with no population.; Care setting: Not applicable (vocabulary); Geography: Not applicable (vocabulary); Life stage: Not applicable (vocabulary); Follow-up: Not applicable (vocabulary)

### The National Library of Medicine vocabulary MeSH defines transient tachypnea of the newborn as an abnormal increase in the newborn's respiratory rate that is self-limiting and attributed to delayed clearance of fetal lung fluid, often after caesarean section delivery.

- Category: Description
- Evidence stage: Evidence stage not applicable
- Certainty: Certainty not assessed
- Applies to: Recipient: No clinical recipient; Population: Not applicable: a controlled-vocabulary definition from the National Library of Medicine, with no population.; Care setting: Not applicable (vocabulary); Geography: Not applicable (vocabulary); Life stage: Not applicable (vocabulary); Follow-up: Not applicable (vocabulary)
- Limitations: A vocabulary definition, not a clinical finding or a diagnostic criterion.
- Last checked: 2026-11-18
- Sources:
  1. Supports: MeSH concept M0549003 (preferred concept of descriptor D059245, Transient Tachypnea of the Newborn) (Dataset, edition MeSH linked-data record of the preferred concept M0549003 of descriptor D059245, fetched 2026-11-18. The scope note is on this concept record, not on the descriptor record. The record states no date.) <https://id.nlm.nih.gov/mesh/M0549003>
     Locator: scopeNote.@value. Retrieved 2026-11-18T21:43:41Z. Source state: Current. Version fingerprint: ce1bb2cf1849eced205dd6241a9fffeda72dd680fbc7d89b4f6390f073e6e995.
     How it applies: MeSH scope note (NLM, attribution given). A definition, not a clinical finding.

## Context: Newborns assessed by lung ultrasound for transient tachypnea of the newborn, in a 2021 meta-analysis

Recipient: Newborn; Population: Newborns in the seven studies (1514 participants) pooled by the authors of a 2021 meta-analysis of lung ultrasound for diagnosing transient tachypnea of the newborn.; Care setting: Neonatal units in diagnostic studies; Geography: Not stated in the abstract; Life stage: Newborn period; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (diagnostic accuracy studies)

### A 2021 meta-analysis of seven studies with 1514 participants found that lung ultrasound had pooled sensitivity of 0.67 and specificity of 0.97 for diagnosing transient tachypnea of the newborn. The authors say that heterogeneity was high, that only seven studies with small samples were included, and that more studies are needed.

- Category: Effect
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Newborn; Population: Newborns in the seven studies (1514 participants) pooled by the authors of a 2021 meta-analysis of lung ultrasound for diagnosing transient tachypnea of the newborn.; Care setting: Neonatal units in diagnostic studies; Geography: Not stated in the abstract; Life stage: Newborn period; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (diagnostic accuracy studies)
- Limitations: Few and small studies with high heterogeneity, as the authors say. The 2026 meta-analysis below reports a much higher sensitivity; the two are not reconciled here.
- Last checked: 2026-11-18
- Sources:
  1. Supports: Diagnostic performance of lung ultrasound for transient tachypnea of the newborn: A meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2021). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC8006999/>
     Locator: Abstract, paragraph 1; Results / Diagnostic accuracy of DLP for TTN, paragraph 1; Conclusions, paragraph 1. Retrieved 2026-11-18T21:42:22Z. Source state: Current. Version fingerprint: 0e402e9ab95a0723cb5c24b14644db8779f65df99b4ccd6977657e365b3669e3.
     How it applies: Full-text open-access review (CC BY 4.0), read in the PMC XML.

## Context: Newborns assessed by lung ultrasound for transient tachypnea of the newborn, in a 2026 meta-analysis

Recipient: Newborn; Population: Newborns in the ten studies (1,747 newborns) pooled by the authors of a 2026 meta-analysis of the accuracy of lung ultrasound for diagnosing transient tachypnea of the newborn. Three of the ten studies were case-control studies.; Care setting: Neonatal units in diagnostic studies; Geography: Not stated in the abstract; Life stage: Newborn period; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (diagnostic accuracy studies)

### A 2026 meta-analysis of ten studies with 1,747 newborns found a pooled sensitivity of 0.93 and specificity of 0.99 for lung ultrasound in diagnosing transient tachypnea of the newborn. The authors conclude that it is promising but that accuracy varies considerably with study design and diagnostic criteria, and they note that three of the ten studies were case-control studies, which may overestimate accuracy.

- Category: Effect
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Newborn; Population: Newborns in the ten studies (1,747 newborns) pooled by the authors of a 2026 meta-analysis of the accuracy of lung ultrasound for diagnosing transient tachypnea of the newborn. Three of the ten studies were case-control studies.; Care setting: Neonatal units in diagnostic studies; Geography: Not stated in the abstract; Life stage: Newborn period; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (diagnostic accuracy studies)
- Limitations: The authors report substantial heterogeneity and a limited sample, and say that case-control designs could overestimate sensitivity and specificity. It is a diagnostic accuracy finding, not a statement about outcomes or about replacing the chest X-ray.
- Last checked: 2026-11-18
- Sources:
  1. Supports: Diagnostic accuracy of lung ultrasound for transient tachypnea of the newborn: a meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13342246/>
     Locator: Abstract / Results, paragraph 1; Abstract / Conclusion, paragraph 1; Discussion, paragraph 4. Retrieved 2026-11-18T21:42:25Z. Source state: Current. Version fingerprint: b1c34137e23630348afb42729088ee1f2300aebf18d0a175c36af867fdb22db4.
     How it applies: Full-text open-access review (CC BY 4.0), read in the PMC XML.

## Context: Near-term and term newborns with transient tachypnea of the newborn, as reviews describe them

Recipient: Newborn; Population: Newborns with transient tachypnea of the newborn (a self-limiting breathing problem from delayed clearance of lung fluid), mostly near-term and term babies, as the authors of reviews describe them.; Care setting: Newborn and neonatal care; Geography: Not stated in the abstracts; Life stage: First days after birth; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (literature reviews)

### A 2026 meta-analysis says that transient tachypnea of the newborn causes fast breathing (over 60 breaths a minute), nasal flaring, grunting and chest retractions soon after birth, and that about 10% of infants born at 33 to 34 weeks are affected, about 5% at 35 to 36 weeks and under 1% at 37 weeks or later.

- Category: Burden
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Newborn; Population: Newborns with transient tachypnea of the newborn (a self-limiting breathing problem from delayed clearance of lung fluid), mostly near-term and term babies, as the authors of reviews describe them.; Care setting: Newborn and neonatal care; Geography: Not stated in the abstracts; Life stage: First days after birth; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (literature reviews)
- Limitations: Figures quoted from the introduction of a review that cites other studies; no country or year is given. The atlas did not read the studies.
- Last checked: 2026-11-18
- Sources:
  1. Supports: Efficacy of nebulized salbutamol in transient tachypnea of the newborn: A systematic review and meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13630241/>
     Locator: Introduction, paragraph 1. Retrieved 2026-11-18T21:42:24Z. Source state: Current. Version fingerprint: d9acdbf67208e79969d96585d1f4b8fdcca114832acfe1d6bbfaf8f5646bff1f.
     How it applies: Full-text open-access review (CC BY 4.0), read in the PMC XML.

### A 2026 meta-analysis describes transient tachypnea of the newborn as a self-limiting respiratory condition caused by delayed clearance of fetal lung fluid, which causes about 33% to 50% of newborn respiratory distress. It says the symptoms are generally transient and typically settle within 24 to 48 hours, and that severe cases may need high-concentration oxygen or even mechanical ventilation. A 2021 meta-analysis adds that the clinical signs overlap with many other conditions.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Newborn; Population: Newborns with transient tachypnea of the newborn (a self-limiting breathing problem from delayed clearance of lung fluid), mostly near-term and term babies, as the authors of reviews describe them.; Care setting: Newborn and neonatal care; Geography: Not stated in the abstracts; Life stage: First days after birth; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (literature reviews)
- Limitations: Statements in the introductions of reviews, which cite studies the atlas did not read. The 33% to 50% share is the authors citation and no country or year is given.
- Last checked: 2026-11-18
- Sources:
  1. Supports: Diagnostic accuracy of lung ultrasound for transient tachypnea of the newborn: a meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13342246/>
     Locator: Introduction, paragraph 1. Retrieved 2026-11-18T21:42:25Z. Source state: Current. Version fingerprint: b1c34137e23630348afb42729088ee1f2300aebf18d0a175c36af867fdb22db4.
     How it applies: Full-text open-access review (CC BY 4.0), read in the PMC XML.
  2. Supports: Diagnostic performance of lung ultrasound for transient tachypnea of the newborn: A meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2021). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC8006999/>
     Locator: Introduction, paragraph 1. Retrieved 2026-11-18T21:42:22Z. Source state: Current. Version fingerprint: 0e402e9ab95a0723cb5c24b14644db8779f65df99b4ccd6977657e365b3669e3.
     How it applies: Full-text open-access review (CC BY 4.0), read in the PMC XML.

## Context: Infants with transient tachypnea of the newborn in randomised trials of nebulized salbutamol, in a 2026 meta-analysis

Recipient: Newborn; Population: Infants with transient tachypnea of the newborn in the 17 randomised trials (1,317 infants) pooled by the authors of a 2026 systematic review and meta-analysis. The review notes that the trials differed in the severity of the infants.; Care setting: Neonatal units in randomised trials; Geography: Not stated in the abstract; Life stage: Newborn period, mostly near-term and term infants; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (meta-analysis of trials)

### A 2026 review with a meta-analysis of 17 randomised trials (1,317 infants) found that nebulized salbutamol shortened respiratory support, CPAP, oxygen need and hospital stay in infants with transient tachypnea of the newborn, but not the duration of fast breathing. The authors rate the certainty of the evidence as low to very low, say the benefit may be limited to more severe cases, and say that other treatments studied have not been adopted as standard practice.

- Category: Effect
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Newborn; Population: Infants with transient tachypnea of the newborn in the 17 randomised trials (1,317 infants) pooled by the authors of a 2026 systematic review and meta-analysis. The review notes that the trials differed in the severity of the infants.; Care setting: Neonatal units in randomised trials; Geography: Not stated in the abstract; Life stage: Newborn period, mostly near-term and term infants; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (meta-analysis of trials)
- Limitations: Low to very low certainty, as the authors say. The atlas read no drug label and no trial for this use, and states no dose or product. Nebulized salbutamol is a drug; whether it is licensed for this use was not checked.
- Last checked: 2026-11-18
- Sources:
  1. Supports: Efficacy of nebulized salbutamol in transient tachypnea of the newborn: A systematic review and meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13630241/>
     Locator: Abstract, paragraph 1; Conclusions, paragraph 1; Introduction, paragraph 5. Retrieved 2026-11-18T21:42:24Z. Source state: Current. Version fingerprint: d9acdbf67208e79969d96585d1f4b8fdcca114832acfe1d6bbfaf8f5646bff1f.
     How it applies: Full-text open-access review (CC BY 4.0), read in the PMC XML.

## Connected pages

- Another cause of newborn breathing trouble, from a different mechanism (surfactant deficiency); MeSH files TTN under newborn respiratory distress: Respiratory distress syndrome in preterm babies (`maternal:neonatal-respiratory-distress-syndrome`)
- The MeSH scope note says it often follows caesarean delivery: Caesarean birth (`maternal:caesarean-birth`)
- The 2026 salbutamol review names CPAP among the support some affected infants need: Continuous positive airway pressure (CPAP) for newborns (`maternal:nasal-cpap`)
- Another cause of newborn breathing trouble that reviews say must be told apart: Meconium aspiration syndrome (`maternal:meconium-aspiration-syndrome`)
- The 2026 review reports higher frequency at 33 to 36 weeks: Preterm birth (`maternal:preterm-birth`)
- Filed under this front: Newborn support: warmth, breathing, feeding (`maternal:front-newborn-support`)

## Registry records

Records a program assembled from a public registry; no person wrote or checked them. They are counted here, not listed: the JSON record of this page lists each one in its relationships.

- 6 registry trials

## Provenance

Content hash: bb0804eaf690f59bdb9d9724eb4613c522a3ad0aad61a49cac2923b4e3365bdc
Last substantive edit: 2026-11-18
Evidence last checked: 2026-11-18
