# Transcutaneous blood gas monitoring in neonates

Technology · id `maternal:transcutaneous-blood-gas-monitoring-neonates` · Maternal & Newborn Atlas · release `8f5d5a5ed7ba4f08` (public)

> General information from published sources, not medical advice, and not reviewed by clinicians. Check the cited source before relying on anything here. Sponsors do not influence what this atlas says.

The atlas's own text and curation may be reused under Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0, https://creativecommons.org/licenses/by-nc/4.0/): credit the atlas, and do not use it commercially without a licence from the owner. See the atlas About page. Text quoted from a source stays under that source's own terms, given as the source's reuse\_basis. The atlas's reuse terms do not cover it. The downloads list each quotation with its source in third\_party\_quotations.

Also called: Transcutaneous PCO2 and PO2 monitoring; tcPCO2 and tcPO2 monitoring; Noninvasive blood gas monitoring in newborns

Browse, life stage: Newborn  
Browse, care area: Preterm and sick newborns  

## In plain language

Transcutaneous blood gas monitoring uses electrodes on the skin to estimate the oxygen and carbon dioxide in the blood without taking a blood sample. A 2005 survey article says skin readings allow continuous monitoring, while conventional blood gas tests cause significant blood loss in preterm babies. Its survey of 41 neonatal units in German-speaking countries found the method widely used, but only 8% of units checked the skin readings against arterial blood gases. A 2016 study of 248 babies born before 33 weeks found a poor match between the skin carbon dioxide reading and the blood value, with the trend agreeing only 39.6% of the time. This page does not cover capillary blood gas sampling and gives no target values.

## Technical summary

Technology page (MeSH D001785, Blood Gas Monitoring, Transcutaneous: exact). Sources read: the MeSH preferred concept scope note (M0002691), the abstract of a 2005 survey of 41 German-speaking neonatal units (PMC1192805, BMC Pediatrics, CC BY 2.0) and the abstract of a 2016 retrospective single-unit study of transcutaneous carbon dioxide in 248 infants born before 33 weeks (PMC4916268, Critical Care Research and Practice, CC BY 4.0). The plan named transcutaneous or capillary blood gas; no source read here covers capillary blood gas sampling in neonates, and the MedlinePlus arterial blood gas page is about arterial sampling and not infants, so capillary sampling is left out. The 2005 survey predates current devices. No target values, sensor settings or alarm limits are stated. Recipient: newborn (preterm).

## Claims, with the population each applies to

## Context: A vocabulary definition (MeSH), not a study population

Recipient: No clinical recipient; Population: Not applicable: a controlled-vocabulary definition from the National Library of Medicine, with no population.; Care setting: Not applicable (vocabulary); Geography: Not applicable (vocabulary); Life stage: Not applicable (vocabulary); Follow-up: Not applicable (vocabulary)

### The National Library of Medicine vocabulary MeSH defines transcutaneous blood gas monitoring as the noninvasive measurement of the partial pressure of oxygen and/or carbon dioxide locally in the capillaries of a tissue, by applying a special set of electrodes to the skin.

- Category: Description
- Evidence stage: Evidence stage not applicable
- Certainty: Certainty not assessed
- Applies to: Recipient: No clinical recipient; Population: Not applicable: a controlled-vocabulary definition from the National Library of Medicine, with no population.; Care setting: Not applicable (vocabulary); Geography: Not applicable (vocabulary); Life stage: Not applicable (vocabulary); Follow-up: Not applicable (vocabulary)
- Limitations: A vocabulary definition, not a clinical criterion; it covers all ages and does not mention newborns. MeSH wording describes the electrodes' photoelectric sensors in more detail, which this page does not repeat.
- Last checked: 2026-11-18
- Sources:
  1. Supports: MeSH concept M0002691 (preferred concept of descriptor D001785, Blood Gas Monitoring, Transcutaneous) (Dataset, edition MeSH linked-data record of the preferred concept M0002691 of descriptor D001785, fetched 2026-11-18. The scope note is on this concept record, not on the descriptor record. The record states no date.) <https://id.nlm.nih.gov/mesh/M0002691>
     Locator: scopeNote.@value. Retrieved 2026-11-18T16:50:04Z. Source state: Current. Version fingerprint: 09d7f7f69b1530316acd2d80ee5eabc7806a21220f22b6a36dc32b5fb2130889.
     How it applies: Passage in the source that backs the claim.

## Context: Premature babies born before 33 weeks in one tertiary neonatal intensive care unit (248 babies, 1365 paired measurements)

Recipient: Newborn; Population: 248 consecutive premature infants born before 33 weeks gestational age (median gestational age 29 weeks 5 days, median birth weight 1250 g), who gave 1365 pairs of transcutaneous and blood carbon dioxide values.; Care setting: A tertiary neonatal intensive care unit; Geography: Not stated in the abstract; Life stage: Premature newborn period; the abstract gives no postnatal ages for the measurements; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Paired transcutaneous and blood measurements during intensive care; a retrospective study

### A 2016 retrospective study in one tertiary neonatal intensive care unit analysed 1365 pairs of transcutaneous carbon dioxide (TcpCO2) and blood carbon dioxide (pCO2) values from 248 consecutive premature infants born before 33 weeks (median gestational age 29 weeks 5 days, median birth weight 1250 g). The Pearson correlation between the values was 0.58, the mean bias was -0.93 kPa with 95% limits of agreement of -4.05 to +2.16 kPa, and the trends of the two values agreed well in only 39.6%. The authors conclude that in premature infants TcpCO2 was poorly correlated with blood pCO2, and warn about clinical decisions based on TcpCO2 alone when it is used as continuous monitoring.

- Category: Effect
- Evidence stage: Observational
- Certainty: Certainty not assessed
- Applies to: Recipient: Newborn; Population: 248 consecutive premature infants born before 33 weeks gestational age (median gestational age 29 weeks 5 days, median birth weight 1250 g), who gave 1365 pairs of transcutaneous and blood carbon dioxide values.; Care setting: A tertiary neonatal intensive care unit; Geography: Not stated in the abstract; Life stage: Premature newborn period; the abstract gives no postnatal ages for the measurements; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Paired transcutaneous and blood measurements during intensive care; a retrospective study
- Limitations: Retrospective and from a single unit, with one device type that the abstract does not name; the results may not apply to other devices, term infants or oxygen readings. The abstract does not give postnatal ages for the measurements. Recipient: newborn (preterm, born before 33 weeks).
- Last checked: 2026-11-18
- Sources:
  1. Supports: Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (Critical Care Research and Practice 2016).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC4916268/>
     Locator: Abstract, Background, sentence 2. Retrieved 2026-11-18T16:45:53Z. Source state: Current. Version fingerprint: dee91e39567bf3453903108cd83d7718027dda57db2fd40e974f3e01167168af.
     How it applies: Passage in the source that backs the claim.
  2. Supports: Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (Critical Care Research and Practice 2016).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC4916268/>
     Locator: Abstract, Methods, sentence 1. Retrieved 2026-11-18T16:45:53Z. Source state: Current. Version fingerprint: dee91e39567bf3453903108cd83d7718027dda57db2fd40e974f3e01167168af.
     How it applies: Passage in the source that backs the claim.
  3. Supports: Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (Critical Care Research and Practice 2016).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC4916268/>
     Locator: Abstract, Methods, sentence 2. Retrieved 2026-11-18T16:45:53Z. Source state: Current. Version fingerprint: dee91e39567bf3453903108cd83d7718027dda57db2fd40e974f3e01167168af.
     How it applies: Passage in the source that backs the claim.
  4. Supports: Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (Critical Care Research and Practice 2016).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC4916268/>
     Locator: Abstract, Results, sentence 1. Retrieved 2026-11-18T16:45:53Z. Source state: Current. Version fingerprint: dee91e39567bf3453903108cd83d7718027dda57db2fd40e974f3e01167168af.
     How it applies: Passage in the source that backs the claim.
  5. Supports: Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (Critical Care Research and Practice 2016).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC4916268/>
     Locator: Abstract, Results, sentence 2. Retrieved 2026-11-18T16:45:53Z. Source state: Current. Version fingerprint: dee91e39567bf3453903108cd83d7718027dda57db2fd40e974f3e01167168af.
     How it applies: Passage in the source that backs the claim.
  6. Supports: Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (Critical Care Research and Practice 2016).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC4916268/>
     Locator: Abstract, Results, sentence 3. Retrieved 2026-11-18T16:45:53Z. Source state: Current. Version fingerprint: dee91e39567bf3453903108cd83d7718027dda57db2fd40e974f3e01167168af.
     How it applies: Passage in the source that backs the claim.
  7. Supports: Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (Critical Care Research and Practice 2016).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC4916268/>
     Locator: Abstract, Results, sentence 4. Retrieved 2026-11-18T16:45:53Z. Source state: Current. Version fingerprint: dee91e39567bf3453903108cd83d7718027dda57db2fd40e974f3e01167168af.
     How it applies: Passage in the source that backs the claim.
  8. Supports: Accuracy of Transcutaneous Carbon Dioxide Measurement in Premature Infants (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (Critical Care Research and Practice 2016).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC4916268/>
     Locator: Abstract, Conclusions, sentences 1 and 3. Retrieved 2026-11-18T16:45:53Z. Source state: Current. Version fingerprint: dee91e39567bf3453903108cd83d7718027dda57db2fd40e974f3e01167168af.
     How it applies: Passage in the source that backs the claim.

## Context: Neonatal intensive care units in Germany, Switzerland and Austria surveyed about transcutaneous blood gas monitoring (41 units answered)

Recipient: Newborn; Population: Neonatal intensive care units: a questionnaire went to 56 head nurses and 41 units gave a complete answer. The survey asks about unit practice and does not describe patients.; Care setting: Neonatal intensive care units; Geography: Germany, Switzerland and Austria; Life stage: Newborn intensive care, with a statement about preterm infants; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (a survey of unit practice)

### A 2005 survey article says that transcutaneous measurements allow continuous, noninvasive monitoring of blood gas levels, while conventional blood gas measurements cause significant blood loss in preterm infants. A questionnaire sent to 56 head nurses in German-speaking neonatal intensive care units was answered completely by 41; transcutaneous measurements were not performed in two of them, and in most units (77%) oxygen and carbon dioxide were measured simultaneously. Only 8% of units obtained arterial blood gases to validate the transcutaneous values. The authors conclude that use of transcutaneous monitors remains widespread in these units, despite earlier data suggesting it had been abandoned in many units worldwide, and that the current way of monitoring oxygenation may not prevent hyperoxaemia in preterm infants.

- Category: Description
- Evidence stage: Observational
- Certainty: Certainty not assessed
- Applies to: Recipient: Newborn; Population: Neonatal intensive care units: a questionnaire went to 56 head nurses and 41 units gave a complete answer. The survey asks about unit practice and does not describe patients.; Care setting: Neonatal intensive care units; Geography: Germany, Switzerland and Austria; Life stage: Newborn intensive care, with a statement about preterm infants; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable (a survey of unit practice)
- Limitations: A 2005 questionnaire from three countries, so it reports practice then, not now, and nurses' answers rather than measured outcomes. It gives no accuracy data. It reports wide variation between units in target oxygen levels, which this page does not repeat as values. Recipient: newborn (neonatal unit practice).
- Last checked: 2026-11-18
- Sources:
  1. Supports: A survey of transcutaneous blood gas monitoring among European neonatal intensive care units (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (BMC Pediatrics 2005).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC1192805/>
     Locator: Abstract, Background, sentence 2. Retrieved 2026-11-18T16:45:52Z. Source state: Current. Version fingerprint: 73647a5c0905e8f02bd37a2619b3f08fd1da21bacbc911baa6bf799550f06a13.
     How it applies: Passage in the source that backs the claim.
  2. Supports: A survey of transcutaneous blood gas monitoring among European neonatal intensive care units (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (BMC Pediatrics 2005).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC1192805/>
     Locator: Abstract, Methods. Retrieved 2026-11-18T16:45:52Z. Source state: Current. Version fingerprint: 73647a5c0905e8f02bd37a2619b3f08fd1da21bacbc911baa6bf799550f06a13.
     How it applies: Passage in the source that backs the claim.
  3. Supports: A survey of transcutaneous blood gas monitoring among European neonatal intensive care units (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (BMC Pediatrics 2005).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC1192805/>
     Locator: Abstract, Results, sentences 1 and 2. Retrieved 2026-11-18T16:45:52Z. Source state: Current. Version fingerprint: 73647a5c0905e8f02bd37a2619b3f08fd1da21bacbc911baa6bf799550f06a13.
     How it applies: Passage in the source that backs the claim.
  4. Supports: A survey of transcutaneous blood gas monitoring among European neonatal intensive care units (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (BMC Pediatrics 2005).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC1192805/>
     Locator: Abstract, Results, sentence 3. Retrieved 2026-11-18T16:45:52Z. Source state: Current. Version fingerprint: 73647a5c0905e8f02bd37a2619b3f08fd1da21bacbc911baa6bf799550f06a13.
     How it applies: Passage in the source that backs the claim.
  5. Supports: A survey of transcutaneous blood gas monitoring among European neonatal intensive care units (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (BMC Pediatrics 2005).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC1192805/>
     Locator: Abstract, Results, sentence 5. Retrieved 2026-11-18T16:45:52Z. Source state: Current. Version fingerprint: 73647a5c0905e8f02bd37a2619b3f08fd1da21bacbc911baa6bf799550f06a13.
     How it applies: Passage in the source that backs the claim.
  6. Supports: A survey of transcutaneous blood gas monitoring among European neonatal intensive care units (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (BMC Pediatrics 2005).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC1192805/>
     Locator: Abstract, Conclusion, sentence 1. Retrieved 2026-11-18T16:45:52Z. Source state: Current. Version fingerprint: 73647a5c0905e8f02bd37a2619b3f08fd1da21bacbc911baa6bf799550f06a13.
     How it applies: Passage in the source that backs the claim.
  7. Supports: A survey of transcutaneous blood gas monitoring among European neonatal intensive care units (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-18 (BMC Pediatrics 2005).) <https://pmc.ncbi.nlm.nih.gov/articles/PMC1192805/>
     Locator: Abstract, Conclusion, sentence 2. Retrieved 2026-11-18T16:45:52Z. Source state: Current. Version fingerprint: 73647a5c0905e8f02bd37a2619b3f08fd1da21bacbc911baa6bf799550f06a13.
     How it applies: Passage in the source that backs the claim.

## Connected pages

- Another technology used in newborn care: Pulse oximetry for newborns (`maternal:neonatal-pulse-oximetry`)
- Another neonatal unit technology: Continuous positive airway pressure (CPAP) for newborns (`maternal:nasal-cpap`)
- Filed under this front: Newborn support: warmth, breathing, feeding (`maternal:front-newborn-support`)
- Related to: Mechanical ventilators for newborns (`maternal:neonatal-ventilators`)

## Provenance

Content hash: c0f77323bfe47bac9519def92dd4e96cb7b038f8d709b6a2c196d369411163ee
Last substantive edit: 2026-11-18
Evidence last checked: 2026-11-18