# Nuchal translucency measurement

Intervention · id `maternal:nuchal-translucency-measurement` · Maternal & Newborn Atlas · release `8f5d5a5ed7ba4f08` (public)

> General information from published sources, not medical advice, and not reviewed by clinicians. Check the cited source before relying on anything here. Sponsors do not influence what this atlas says.

The atlas's own text and curation may be reused under Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0, https://creativecommons.org/licenses/by-nc/4.0/): credit the atlas, and do not use it commercially without a licence from the owner. See the atlas About page. Text quoted from a source stays under that source's own terms, given as the source's reuse\_basis. The atlas's reuse terms do not cover it. The downloads list each quotation with its source in third\_party\_quotations.

Also called: NT

Browse, life stage: Pregnancy  
Browse, care area: Routine pregnancy care; The baby before birth  

## In plain language

Nuchal translucency (NT) is a measurement, made on a first-trimester ultrasound scan, of the fluid-filled space at the back of the unborn baby's neck. A 2024 review places the scan between 11 weeks and 13 weeks 6 days of pregnancy and says it is already part of the usual first-trimester screening for chromosomal abnormalities, namely Down syndrome. Reviews say an increased measurement is linked with chromosomal anomalies, heart defects and central nervous system anomalies in the fetus, and that there is debate on the cut-off for calling it increased. This page gives no advice on tests or decisions.

## Technical summary

Intervention, subtype test. MeSH D048208 (Nuchal Translucency Measurement) is the same concept, so the match is exact. The plan's title, first-trimester combined screening and nuchal translucency, was narrowed to the measurement: none of the three reviews read describes combined screening (NT with blood markers), so no combined-screening claim is made. Sources read, all CC BY 4.0: a 2024 review of NT and congenital heart defects (PMC11107467), a 2026 meta-analysis of fetuses with NT of 3.0 to 3.4 mm (PMC13487402), a 2026 meta-analysis of NT and central nervous system anomalies in euploid fetuses (PMC13163124), and the MeSH scope note. Cut-offs are reported as the reviews state them; no society advice on follow-up testing is relayed. The recipient is the fetus on every claim.

## Claims, with the population each applies to

## Context: Euploid fetuses with increased nuchal translucency in a 2026 meta-analysis of central nervous system anomalies

Recipient: Fetal; Population: Singleton pregnancies with increased nuchal translucency between 10 and 14 weeks and normal chromosomes (euploid fetuses): 23 studies and 15,592 pregnancies, with three comparative studies of 6040 pregnancies with increased nuchal translucency against 152,682 with normal nuchal translucency.; Care setting: Not stated in the source.; Geography: Not stated in the source.; Life stage: Pregnancy, first trimester scan with later ultrasound; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### A 2026 systematic review and meta-analysis covering 23 studies (15,592 euploid pregnancies with increased NT) found a pooled prevalence of central nervous system anomalies of 1.16% (95% CI 0.68 to 1.95). In three comparative studies, increased NT was associated with higher odds of these anomalies than normal NT (odds ratio 3.22, 95% CI 1.52 to 6.80).

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Fetal; Population: Singleton pregnancies with increased nuchal translucency between 10 and 14 weeks and normal chromosomes (euploid fetuses): 23 studies and 15,592 pregnancies, with three comparative studies of 6040 pregnancies with increased nuchal translucency against 152,682 with normal nuchal translucency.; Care setting: Not stated in the source.; Geography: Not stated in the source.; Life stage: Pregnancy, first trimester scan with later ultrasound; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: Heterogeneity was high (I2 80% for the prevalence and 74.1% for the comparison) and the definition of increased NT varied between studies. The review states that euploid fetuses with increased NT may have a higher risk. Not an assessment of any test.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Association Between Increased Nuchal Translucency and Foetal CNS Abnormalities in Euploid Foetuses: Systematic Review and Meta-Analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13163124/>
     Locator: Abstract, paragraph 1, sentence 6. Retrieved 2026-11-19T00:30:19Z. Source state: Current. Version fingerprint: 2ad2d066fc32839127bb42c434d7413a07f5df63bcf294cf93599d33a9e0d10c.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  2. Supports: Association Between Increased Nuchal Translucency and Foetal CNS Abnormalities in Euploid Foetuses: Systematic Review and Meta-Analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13163124/>
     Locator: Abstract, paragraph 1, sentence 8. Retrieved 2026-11-19T00:30:19Z. Source state: Current. Version fingerprint: 2ad2d066fc32839127bb42c434d7413a07f5df63bcf294cf93599d33a9e0d10c.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  3. Supports: Association Between Increased Nuchal Translucency and Foetal CNS Abnormalities in Euploid Foetuses: Systematic Review and Meta-Analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13163124/>
     Locator: Abstract, paragraph 1, sentence 9. Retrieved 2026-11-19T00:30:19Z. Source state: Current. Version fingerprint: 2ad2d066fc32839127bb42c434d7413a07f5df63bcf294cf93599d33a9e0d10c.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  4. Background: Association Between Increased Nuchal Translucency and Foetal CNS Abnormalities in Euploid Foetuses: Systematic Review and Meta-Analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13163124/>
     Locator: Abstract, paragraph 1, sentence 7. Retrieved 2026-11-19T00:30:19Z. Source state: Current. Version fingerprint: 2ad2d066fc32839127bb42c434d7413a07f5df63bcf294cf93599d33a9e0d10c.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  5. Background: Association Between Increased Nuchal Translucency and Foetal CNS Abnormalities in Euploid Foetuses: Systematic Review and Meta-Analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13163124/>
     Locator: Abstract, paragraph 1, sentence 1. Retrieved 2026-11-19T00:30:19Z. Source state: Current. Version fingerprint: 2ad2d066fc32839127bb42c434d7413a07f5df63bcf294cf93599d33a9e0d10c.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  6. Background: Association Between Increased Nuchal Translucency and Foetal CNS Abnormalities in Euploid Foetuses: Systematic Review and Meta-Analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13163124/>
     Locator: Abstract, paragraph 1, sentence 4. Retrieved 2026-11-19T00:30:19Z. Source state: Current. Version fingerprint: 2ad2d066fc32839127bb42c434d7413a07f5df63bcf294cf93599d33a9e0d10c.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

## Context: Fetuses having a nuchal translucency measurement, as a 2024 review and a 2026 meta-analysis describe it

Recipient: Fetal; Population: Fetuses during the first trimester. The reviews describe the measurement and how it is used in screening and give no single study group.; Care setting: Not stated in the sources.; Geography: Not stated in the sources.; Life stage: First trimester of pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### A 2024 review says NT is considered above normal when it is higher than the 95th or 99th percentile, or at 2.5 or 3.5 mm and above. A 2026 meta-analysis says there is debate on how to define an increased NT: some professional societies suggest a percentile and others prefer a fixed cut-off of 3.0 or 3.5 mm.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Fetal; Population: Fetuses during the first trimester. The reviews describe the measurement and how it is used in screening and give no single study group.; Care setting: Not stated in the sources.; Geography: Not stated in the sources.; Life stage: First trimester of pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: Two reviews describing how an increased NT is defined. Neither gives a single accepted cut-off. This page does not say which value to use or what follows from any value.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Nuchal Translucency and Congenital Heart Defects (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2024). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC11107467/>
     Locator: Abstract, paragraph 1, sentence 2. Retrieved 2026-11-19T00:30:16Z. Source state: Current. Version fingerprint: d634888ee535dc6a8397a3387dcff9ab74d7c454d11432238dbb1b001d9ec9f3.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  2. Supports: Chromosomal and genetic anomalies in fetuses with nuchal translucency between 3.0 and 3.4 mm: A systematic review and meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13487402/>
     Locator: INTRODUCTION, paragraph 3, sentence 1. Retrieved 2026-11-19T00:30:17Z. Source state: Current. Version fingerprint: 84a3e1065fecc936d12eb63013edb0c9890239e5fbe8b796f35379198cd8ade9.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

### A 2024 review describes nuchal translucency (NT) as a temporary build-up of fluid under the skin at the back of the fetal neck, seen on an ultrasound scan between 11 weeks and 13 weeks 6 days of pregnancy. MeSH describes the measurement as a prenatal ultrasound measurement of the soft tissue behind the fetal neck.

- Category: Description
- Evidence stage: Evidence stage not applicable
- Certainty: Certainty not assessed
- Applies to: Recipient: Fetal; Population: Fetuses during the first trimester. The reviews describe the measurement and how it is used in screening and give no single study group.; Care setting: Not stated in the sources.; Geography: Not stated in the sources.; Life stage: First trimester of pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: Definitions from a review and a vocabulary. They give no measurement technique, training or quality standard.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Nuchal Translucency and Congenital Heart Defects (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2024). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC11107467/>
     Locator: INTRODUCTION, paragraph 1, sentence 1. Retrieved 2026-11-19T00:30:16Z. Source state: Current. Version fingerprint: d634888ee535dc6a8397a3387dcff9ab74d7c454d11432238dbb1b001d9ec9f3.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  2. Supports: Nuchal Translucency and Congenital Heart Defects (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2024). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC11107467/>
     Locator: Abstract, paragraph 1, sentence 1. Retrieved 2026-11-19T00:30:16Z. Source state: Current. Version fingerprint: d634888ee535dc6a8397a3387dcff9ab74d7c454d11432238dbb1b001d9ec9f3.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  3. Supports: MeSH concept M0460913 (Nuchal Translucency Measurement) (Dataset, edition MeSH linked-data concept record as fetched on 2026-10-25. It holds the concept label and its scope note, and states no date.) <https://id.nlm.nih.gov/mesh/M0460913>
     Locator: scopeNote.@value. Retrieved 2026-10-25T15:28:34Z. Source state: Current. Version fingerprint: 30c9f539f4956eb3a42e33bd91710df0f78ef484cce3bf52fdb2d9434e2a52a0.
     How it applies: MeSH scope note (NLM, attribution given). A definition, not a clinical finding.

### A 2024 review says an NT ultrasound is already part of the usual first-trimester screening for chromosomal abnormalities, namely Down syndrome. A 2026 meta-analysis calls NT a core component of first-trimester screening for chromosomal anomalies for 40 years and says the current trend favours measuring NT first, then cell-free DNA testing in people judged to be at low risk.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Fetal; Population: Fetuses during the first trimester. The reviews describe the measurement and how it is used in screening and give no single study group.; Care setting: Not stated in the sources.; Geography: Not stated in the sources.; Life stage: First trimester of pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: Statements about practice in two reviews, not a guideline. Neither review describes the combined first-trimester test (NT with blood markers) or gives its detection rate, and this page does not either.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Nuchal Translucency and Congenital Heart Defects (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2024). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC11107467/>
     Locator: INTRODUCTION, paragraph 1, sentence 4. Retrieved 2026-11-19T00:30:16Z. Source state: Current. Version fingerprint: d634888ee535dc6a8397a3387dcff9ab74d7c454d11432238dbb1b001d9ec9f3.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  2. Supports: Chromosomal and genetic anomalies in fetuses with nuchal translucency between 3.0 and 3.4 mm: A systematic review and meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13487402/>
     Locator: INTRODUCTION, paragraph 1, sentence 1. Retrieved 2026-11-19T00:30:17Z. Source state: Current. Version fingerprint: 84a3e1065fecc936d12eb63013edb0c9890239e5fbe8b796f35379198cd8ade9.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  3. Supports: Chromosomal and genetic anomalies in fetuses with nuchal translucency between 3.0 and 3.4 mm: A systematic review and meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13487402/>
     Locator: INTRODUCTION, paragraph 2, sentence 1. Retrieved 2026-11-19T00:30:17Z. Source state: Current. Version fingerprint: 84a3e1065fecc936d12eb63013edb0c9890239e5fbe8b796f35379198cd8ade9.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

## Context: Fetuses with increased nuchal translucency and congenital heart defects, as a 2024 review describes them

Recipient: Fetal; Population: Fetuses with increased nuchal translucency in studies of congenital heart defects. The 2024 review searched PubMed (PRISMA 2020) and describes the studies it covers without a single study group.; Care setting: Not stated in the source.; Geography: Not stated in the source.; Life stage: First trimester measurement; heart defects found before or after birth; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### A 2024 review says there is great variability in the NT cut-off values proposed for detecting congenital heart defects. It cites a meta-analysis in which sensitivity for these defects was 37% with a 95th percentile cut-off and 31% with a 99th percentile cut-off.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Fetal; Population: Fetuses with increased nuchal translucency in studies of congenital heart defects. The 2024 review searched PubMed (PRISMA 2020) and describes the studies it covers without a single study group.; Care setting: Not stated in the source.; Geography: Not stated in the source.; Life stage: First trimester measurement; heart defects found before or after birth; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: The sensitivity figures are cited by the review from another meta-analysis and were not checked against it. It is a review of a PubMed search with no pooled estimate of its own. No specificity or guideline advice is given here.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Nuchal Translucency and Congenital Heart Defects (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2024). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC11107467/>
     Locator: Abstract, paragraph 1, sentence 5. Retrieved 2026-11-19T00:30:16Z. Source state: Current. Version fingerprint: d634888ee535dc6a8397a3387dcff9ab74d7c454d11432238dbb1b001d9ec9f3.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  2. Supports: Nuchal Translucency and Congenital Heart Defects (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2024). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC11107467/>
     Locator: INTRODUCTION, paragraph 9, sentence 2. Retrieved 2026-11-19T00:30:16Z. Source state: Current. Version fingerprint: d634888ee535dc6a8397a3387dcff9ab74d7c454d11432238dbb1b001d9ec9f3.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

## Context: Fetuses with a nuchal translucency of 3.0 to 3.4 mm in studies that had invasive prenatal testing or postnatal genetic assessment

Recipient: Fetal; Population: Fetuses with a nuchal translucency between 3.0 and 3.4 mm, pooled from 17 studies (7007 fetuses). The studies included fetuses that had invasive prenatal testing or postnatal genetic assessment, so the group is selected.; Care setting: Not stated in the source.; Geography: Not stated in the source.; Life stage: Pregnancy, first trimester scan with later testing; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### A 2026 systematic review and meta-analysis covering 17 studies (7007 fetuses) with an NT between 3.0 and 3.4 mm found chromosomal anomalies in 13.1% (95% CI 9.3 to 17.3). Its authors conclude that most of the chromosomal anomalies and copy number variants could potentially be detected by cell-free DNA testing.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Fetal; Population: Fetuses with a nuchal translucency between 3.0 and 3.4 mm, pooled from 17 studies (7007 fetuses). The studies included fetuses that had invasive prenatal testing or postnatal genetic assessment, so the group is selected.; Care setting: Not stated in the source.; Geography: Not stated in the source.; Life stage: Pregnancy, first trimester scan with later testing; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: The fetuses come from studies of people who had invasive prenatal testing or postnatal genetic assessment, so 13.1% is not the rate among all fetuses with this NT. The detection statement is the authors’ own and says potentially. Rates for single anomaly types are not repeated here.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Chromosomal and genetic anomalies in fetuses with nuchal translucency between 3.0 and 3.4 mm: A systematic review and meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13487402/>
     Locator: Abstract, Results, paragraph 1, sentence 1. Retrieved 2026-11-19T00:30:17Z. Source state: Current. Version fingerprint: 84a3e1065fecc936d12eb63013edb0c9890239e5fbe8b796f35379198cd8ade9.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  2. Supports: Chromosomal and genetic anomalies in fetuses with nuchal translucency between 3.0 and 3.4 mm: A systematic review and meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13487402/>
     Locator: Abstract, Results, paragraph 1, sentence 2. Retrieved 2026-11-19T00:30:17Z. Source state: Current. Version fingerprint: 84a3e1065fecc936d12eb63013edb0c9890239e5fbe8b796f35379198cd8ade9.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  3. Supports: Chromosomal and genetic anomalies in fetuses with nuchal translucency between 3.0 and 3.4 mm: A systematic review and meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13487402/>
     Locator: Abstract, Conclusions, paragraph 1, sentence 1. Retrieved 2026-11-19T00:30:17Z. Source state: Current. Version fingerprint: 84a3e1065fecc936d12eb63013edb0c9890239e5fbe8b796f35379198cd8ade9.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.
  4. Background: Chromosomal and genetic anomalies in fetuses with nuchal translucency between 3.0 and 3.4 mm: A systematic review and meta-analysis (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2026). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC13487402/>
     Locator: Abstract, Material and Methods, paragraph 1, sentence 2. Retrieved 2026-11-19T00:30:17Z. Source state: Current. Version fingerprint: 84a3e1065fecc936d12eb63013edb0c9890239e5fbe8b796f35379198cd8ade9.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

## Connected pages

- The measurement is made on an ultrasound scan: Pregnancy ultrasound (`maternal:obstetric-ultrasound`)
- Described by a 2024 review as part of first-trimester screening for Down syndrome: Down syndrome (`maternal:down-syndrome`) [a claim, not a settled fact; see claim `maternal:claim-w46c-nt-screening` and its context]
- Related page: cell-free DNA screening: Cell-free DNA screening for fetal chromosome conditions (`maternal:cell-free-dna-screening`)
- Related page: fetal echocardiography: Fetal echocardiography (`maternal:fetal-echocardiography`)
- Filed under this front: Screening and tests (`maternal:front-screening-and-tests`)
- Related to: Mid-pregnancy anomaly scan (18 to 20 week ultrasound) (`maternal:mid-pregnancy-anomaly-scan`)

## Provenance

Content hash: a6097bd08260a6d4195d60d81ebbc12cfe68f3c7edee660eddbe57837854a3fd
Last substantive edit: 2026-11-19
Evidence last checked: 2026-11-19