The atlas's own text and curation may be reused under Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0, https://creativecommons.org/licenses/by-nc/4.0/): credit the atlas, and do not use it commercially without a licence from the owner. See the atlas About page. Text quoted from a source stays under that source's own terms, given as the source's reuse\_basis. The atlas's reuse terms do not cover it. The downloads list each quotation with its source in third\_party\_quotations.

Also called: fFN test; Fetal fibronectin; Cervicovaginal fetal fibronectin

Browse, life stage: Pregnancy  
Browse, care area: Pregnancy conditions  

## In plain language

The fetal fibronectin test looks for fetal fibronectin, a protein made by cells of the fetal membranes, in fluid from the cervix and vagina. A 2018 overview says it is normally found before 22 weeks and that finding it from 24 to 34 weeks indicates a risk of preterm birth. It says the test is most accurate for women with threatened preterm labour whose cervix is not far opened, predicting birth within 7 to 10 days, but that a meta-analysis found testing did not prevent preterm birth or improve outcomes in single-baby pregnancies, and that no single biomarker is both sensitive and reliable. Other bedside tests exist and one meta-analysis ranked them differently. A US National Institutes of Health (NICHD) page, last reviewed in 2023, says the test is mostly done in women showing signs of preterm labour and is typically used for its negative predictive value: a negative result means birth within the next 7 days is unlikely. This page gives no advice on whether or when to test.

## Technical summary

Technology (a laboratory test of cervicovaginal fluid). MeSH D005353 (Fibronectins) is the class of proteins, not the test, so the match is broad; its scope note does not mention pregnancy. Sources read: the MeSH scope note and the full text of a 2018 narrative overview of preterm birth prediction (PMC6199875, CC BY 4.0, read in full; the full permissions element states no non-commercial or no-derivatives wording). Used: the biomarker section on cervical fluid, the abstract and the conclusion. Not used: the maternal characteristics, ultrasound, amniotic fluid, serum and molecular sections, apart from cervical length where the overview compares it with the test. The overview gives sensitivity and specificity for other tests in places and none is recorded for fetal fibronectin, because it gives none in the passages read. A second source is the NICHD page on diagnosing preterm labor (last reviewed 2023-05-09, public domain), which describes the protein, when it is normally found, who is usually tested and the test's use for its negative predictive value, without figures; it is cited in its own claim. No kit, manufacturer or regulatory status is described. Each claim states its recipient (the woman tested, or mother and baby for outcomes).

## Claims, with the population each applies to

## Context: Pregnant women without symptoms and at low risk, and women who have had a preterm birth before or have symptoms, as a 2018 overview describes screening

Recipient: Maternal; Population: Two groups the overview names: asymptomatic women at low risk of preterm birth, and women who have had a preterm birth before or who have symptoms of threatened preterm birth. The overview gives no study group.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### The 2018 overview concludes that not a single biomarker has been found which has both sensitivity and reliability for detecting spontaneous preterm birth, that there is no routine method recommended for screening for preterm birth in asymptomatic low-risk women, and that transvaginal ultrasound measurement of cervical length is the only cost-effective method in women who have had a preterm birth before or who have symptoms of threatened preterm birth.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Maternal; Population: Two groups the overview names: asymptomatic women at low risk of preterm birth, and women who have had a preterm birth before or who have symptoms of threatened preterm birth. The overview gives no study group.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: The overview's own conclusion from a narrative review, not a guideline; some of its statements about recommendations are about all screening methods and not about this test. The overview is from 2018, and later guidance was not read here.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Prediction of Preterm Birth: Maternal Characteristics, Ultrasound Markers, and Biomarkers: An Updated Overview (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2018). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC6199875/>
     Locator: 6. Conclusion, paragraph 2, sentence 1; 6. Conclusion, paragraph 5, sentence 2; 6. Conclusion, paragraph 5, sentence 3. Retrieved 2026-11-19T02:20:43Z. Source state: Current. Version fingerprint: fed0cda72f6d2d4771b9c3e71dac389bb7447ffb1cc99db3d6ec4e707f07e9a0.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

## Context: Pregnant women and their fetal membranes, as a 2018 overview describes fetal fibronectin

Recipient: Mixed recipients; Population: Pregnant women and fetuses: the protein is made by cells of the fetal membranes and binds them to the mother's uterine lining. The overview describes this in general and gives no study group.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### MeSH describes fibronectins as glycoproteins found on the surfaces of cells, particularly in fibrillar structures. A 2018 overview describes fetal fibronectin as a glycoprotein produced by amniocytes and cytotrophoblasts that binds the chorionic membranes to the maternal decidua.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Mixed recipients; Population: Pregnant women and fetuses: the protein is made by cells of the fetal membranes and binds them to the mother's uterine lining. The overview describes this in general and gives no study group.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: The MeSH note is about the whole class of proteins and does not mention pregnancy, which is why the MeSH match for this page is broad. The overview gives no figures for this statement.
- Last checked: 2026-11-19
- Sources:
  1. Supports: MeSH concept M0008450 (preferred concept of descriptor D005353, Fibronectins) (Dataset, edition MeSH linked-data record of the preferred concept M0008450 of descriptor D005353, fetched 2026-11-19. The scope note is on this concept record, not on the descriptor record. The record states no date.) <https://id.nlm.nih.gov/mesh/M0008450>
     Locator: scopeNote.@value. Retrieved 2026-11-19T02:20:57Z. Source state: Current. Version fingerprint: cb2534d22529a5c2a134d7ca149f8752cbaecf33e08269f76eafb258c9859969.
     How it applies: MeSH scope note (NLM, attribution given). A definition, not a clinical finding.
  2. Supports: Prediction of Preterm Birth: Maternal Characteristics, Ultrasound Markers, and Biomarkers: An Updated Overview (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2018). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC6199875/>
     Locator: 4. Biomarkers &gt; 4.1. Cervical Fluid, paragraph 1, sentence 1. Retrieved 2026-11-19T02:20:43Z. Source state: Current. Version fingerprint: fed0cda72f6d2d4771b9c3e71dac389bb7447ffb1cc99db3d6ec4e707f07e9a0.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

## Context: Pregnant women tested in different ways, as a 2018 overview reports studies on the test

Recipient: Maternal; Population: Pregnant women in the studies the overview cites: women with blood-stained swabs, women tested with a quantitative result and a cervical length, and nulliparous women. The overview gives no study group for each.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### The 2018 overview says that when fetal fibronectin was tested on blood-stained swabs they were still effective in predicting preterm birth but had higher false-positive rates. It says combining a quantitative fetal fibronectin result with cervical length did not improve the prediction of delivery in the following 7 days, though it added value in determining a risk range, and that the accuracy of combining serial cervical length measurements with fetal fibronectin in nulliparous women was reported to be low.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Maternal; Population: Pregnant women in the studies the overview cites: women with blood-stained swabs, women tested with a quantitative result and a cervical length, and nulliparous women. The overview gives no study group for each.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: Each statement is one study reported in one sentence by the overview, with no figures; the studies were not read. The overview does not give the group sizes.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Prediction of Preterm Birth: Maternal Characteristics, Ultrasound Markers, and Biomarkers: An Updated Overview (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2018). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC6199875/>
     Locator: 4. Biomarkers &gt; 4.1. Cervical Fluid, paragraph 2, sentence 1; 4. Biomarkers &gt; 4.1. Cervical Fluid, paragraph 3, sentence 1; 4. Biomarkers &gt; 4.1. Cervical Fluid, paragraph 3, sentence 2. Retrieved 2026-11-19T02:20:43Z. Source state: Current. Version fingerprint: fed0cda72f6d2d4771b9c3e71dac389bb7447ffb1cc99db3d6ec4e707f07e9a0.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

## Context: Pregnant women showing signs of preterm labour, as an NICHD page describes the fetal fibronectin test

Recipient: Maternal; Population: Pregnant women, mostly those showing signs of preterm labour, as the NICHD page describes who is usually tested. It gives no study group.; Care setting: Not stated in the source.; Geography: Not stated in the source.; Life stage: Pregnancy, between 24 and 34 weeks in the statement on a positive result; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### An NICHD page (last reviewed in May 2023) says the test detects whether the protein fetal fibronectin is being produced, and likens the protein to a biological glue between the uterine lining and the membrane around the fetus. It says fetal fibronectin is normally detectable in secretions from the vagina and cervix up to 22 weeks of pregnancy and again 1 to 3 weeks before labour begins, is usually not present between 24 and 34 weeks, and that finding it during that time may be a sign of risk of preterm labour and birth. It says the test is mostly done in women showing signs of preterm labour and is typically used for its negative predictive value: "if it is negative, it is unlikely that a woman will deliver within the next 7 days".

- Category: Description
- Evidence stage: Guidance
- Certainty: Certainty not assessed
- Applies to: Recipient: Maternal; Population: Pregnant women, mostly those showing signs of preterm labour, as the NICHD page describes who is usually tested. It gives no study group.; Care setting: Not stated in the source.; Geography: Not stated in the source.; Life stage: Pregnancy, between 24 and 34 weeks in the statement on a positive result; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: A general health-information page with no figures; it cites a 2008 Cochrane review and a 1996 study that were not read. It gives no cut-off, assay or accuracy figures. The atlas gives no advice on whether or when to test.
- Last checked: 2026-11-19
- Sources:
  1. Supports: How do health care providers diagnose preterm labor? (NICHD health topic subpage) (Webpage, edition NICHD health topic subpage, fetched on 2026-11-19. The page states a Last Reviewed Date of 5/9/2023. Only the NICHD text of the fetal fibronectin section is used; its two citations (a 2008 Cochrane review and a 1996 study) are not read or quoted.) <https://www.nichd.nih.gov/health/topics/preterm/conditioninfo/diagnosed>
     Locator: Fetal Fibronectin (fFN) Test, paragraphs 1 to 3. Retrieved 2026-11-19T02:41:33Z. Source state: Current. Version fingerprint: b533f8304cb928e2c314b4479d0e28c5a5dbc0be843d8fe137bfab23015fdfd2.
     How it applies: NICHD health topic page (public domain, courtesy of NICHD).

## Context: Women with a single baby, as a 2018 overview reports a meta-analysis of fetal fibronectin testing

Recipient: Mixed recipients; Population: Women with singleton pregnancies tested for fetal fibronectin, and the outcomes the meta-analysis counted (preterm birth and perinatal outcomes for their babies). The overview reports the meta-analysis in one sentence and gives no figures.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy and the perinatal period; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### The 2018 overview cites a recent meta-analysis which reported that fetal fibronectin testing in singleton pregnancies was not associated with prevention of preterm birth or improved perinatal outcomes, and that the rates of preterm birth before 28, 32, 34 and 37 weeks did not change despite the higher costs.

- Category: Effect
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Mixed recipients; Population: Women with singleton pregnancies tested for fetal fibronectin, and the outcomes the meta-analysis counted (preterm birth and perinatal outcomes for their babies). The overview reports the meta-analysis in one sentence and gives no figures.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy and the perinatal period; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: One meta-analysis reported in one sentence; it was not read here, and the overview gives no figures. The statement is about whether testing changes outcomes, not about whether the test identifies women who deliver early.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Prediction of Preterm Birth: Maternal Characteristics, Ultrasound Markers, and Biomarkers: An Updated Overview (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2018). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC6199875/>
     Locator: 4. Biomarkers &gt; 4.1. Cervical Fluid, paragraph 1, sentence 4. Retrieved 2026-11-19T02:20:43Z. Source state: Current. Version fingerprint: fed0cda72f6d2d4771b9c3e71dac389bb7447ffb1cc99db3d6ec4e707f07e9a0.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

## Context: Women with threatened preterm labour, as a 2018 overview describes the test

Recipient: Maternal; Population: Pregnant women with symptoms of threatened preterm labour, without advanced cervical dilatation in the statement on accuracy. The overview cites systematic reviews and gives no single study group.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy, between 24 and 34 weeks in the statement on the test result; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.

### The 2018 overview cites a systematic review which reported that the accuracy of fetal fibronectin in predicting spontaneous preterm birth varied, and that it is most accurate in women with threatened preterm labour without advanced cervical dilatation, for birth within 7 to 10 days after testing.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Maternal; Population: Pregnant women with symptoms of threatened preterm labour, without advanced cervical dilatation in the statement on accuracy. The overview cites systematic reviews and gives no single study group.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy, between 24 and 34 weeks in the statement on the test result; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: The overview gives no sensitivity, specificity or predictive values for this test in the passages read; the systematic review is the overview's citation and was not read here. The overview says the accuracy varied.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Prediction of Preterm Birth: Maternal Characteristics, Ultrasound Markers, and Biomarkers: An Updated Overview (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2018). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC6199875/>
     Locator: 4. Biomarkers &gt; 4.1. Cervical Fluid, paragraph 1, sentence 3. Retrieved 2026-11-19T02:20:43Z. Source state: Current. Version fingerprint: fed0cda72f6d2d4771b9c3e71dac389bb7447ffb1cc99db3d6ec4e707f07e9a0.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

### The 2018 overview says bedside tests have also been developed for insulin-like growth factor binding protein-1, interleukin-6 and placental alpha-macroglobulin-1. It reports a recent meta-analysis in symptomatic women that compared placental alpha-macroglobulin-1, fetal fibronectin and phosphorylated insulin-like growth factor binding protein-1 and found placental alpha-macroglobulin-1 to have the highest positive predictive value and positive likelihood ratio.

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Maternal; Population: Pregnant women with symptoms of threatened preterm labour, without advanced cervical dilatation in the statement on accuracy. The overview cites systematic reviews and gives no single study group.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy, between 24 and 34 weeks in the statement on the test result; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: One meta-analysis reported in one sentence, not read here; the overview gives no figures. The overview says negative predictive value and the negative likelihood ratio were similarly high for the three markers.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Prediction of Preterm Birth: Maternal Characteristics, Ultrasound Markers, and Biomarkers: An Updated Overview (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2018). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC6199875/>
     Locator: Abstract, paragraph 1, sentence 3; 4. Biomarkers &gt; 4.1. Cervical Fluid, paragraph 7, sentence 1. Retrieved 2026-11-19T02:20:43Z. Source state: Current. Version fingerprint: fed0cda72f6d2d4771b9c3e71dac389bb7447ffb1cc99db3d6ec4e707f07e9a0.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

### The 2018 overview says fetal fibronectin is normally found in cervicovaginal fluid before 22 weeks of gestation, and that finding it in cervicovaginal fluid from 24 to 34 weeks of gestation indicates a risk of preterm birth (delivery before 37 weeks).

- Category: Description
- Evidence stage: Evidence synthesis
- Certainty: Certainty not assessed
- Applies to: Recipient: Maternal; Population: Pregnant women with symptoms of threatened preterm labour, without advanced cervical dilatation in the statement on accuracy. The overview cites systematic reviews and gives no single study group.; Care setting: Not stated in the source.; Geography: Not stated in the overview.; Life stage: Pregnancy, between 24 and 34 weeks in the statement on the test result; Gestational age: Not reported; Postnatal age: Not reported; Follow-up: Not applicable: a statement in a review or health-information page, not a study with follow-up.
- Limitations: The overview gives no cut-off for a positive result, no assay and no figures in these sentences, and the atlas records none. A risk indication is not a prediction for an individual woman.
- Last checked: 2026-11-19
- Sources:
  1. Supports: Prediction of Preterm Birth: Maternal Characteristics, Ultrasound Markers, and Biomarkers: An Updated Overview (Publication, edition PMC Open Access subset full-text XML from NCBI E-utilities, retrieved 2026-11-19 (2018). Used: abstract and selected paragraphs.) <https://pmc.ncbi.nlm.nih.gov/articles/PMC6199875/>
     Locator: 4. Biomarkers &gt; 4.1. Cervical Fluid, paragraph 1, sentence 2. Retrieved 2026-11-19T02:20:43Z. Source state: Current. Version fingerprint: fed0cda72f6d2d4771b9c3e71dac389bb7447ffb1cc99db3d6ec4e707f07e9a0.
     How it applies: Full-text open-access article (CC BY 4.0), read in the PMC XML.

## Connected pages

- Evaluated as a bedside test to predict preterm birth, with variable accuracy, in a 2018 overview: Preterm birth (`maternal:preterm-birth`) [a claim, not a settled fact; see claim `maternal:claim-w48c-ffn-accuracy` and its context]
- The 2018 overview compares and combines fetal fibronectin with cervical length measurement (existing page on cervical length measurement): Cervical length measurement (`maternal:cervical-length-measurement`)
- The overview names cervical length as the other main predictor of preterm birth (existing page on short cervix): Short cervix (`maternal:short-cervix`)
- Filed under this front: Screening and tests (`maternal:front-screening-and-tests`)

## Provenance

Content hash: d049f35a45e48cdb423ba3d9b43d417a21baed9c663f0e8c25720ba0f531e7f9
Last substantive edit: 2026-11-19
Evidence last checked: 2026-11-19